29
PROBLEM
CAUSE
SOLUTION
Pump not
running
No power to
spa
Reset circuit breakers on GFCI panel
and main circuit breaker panel
Water does
Air lock
Bleed air from the system (page 27)
not flow
Closed Jets
Open all jets by turning
counterclockwise
ACV open
Close air control valves
Water too
hot
High set
temperature
Turn down set temperature on
topside control panel
High
ambient
temperature
Remove the cover from the spa
Water will
not heat
Thermostat is
set too low
Check and reset to desired
temperature
Air open
Close air control valve
Dirty filter
Check and clean filter
Blown fuse
Check and replace fuse
Slide valve
closed
Check and open all valves
Cover off
Put cover back on spa
Spa in
Economy
mode
Press the Standby button and take
spa out of Economy (see
Economy
Mode
on page 21)
Error Codes
MESSAGE MEANING
ACTION REQUIRED
(none
)
No message on
display. Power has
been cut off to spa.
The control panel will be
disabled until power returns.
Spa settings are preserved
HH
The spa has shut down
from high heat
detection. One of the
sensors detected 118ºF
(48ºC) at the heater.
Do not enter the water.
Remove the spa cover and
allow the water to cool. Once
the heater has cooled, reset
by pushing any button. If the
spa does not reset, shut off
the power to the spa and call
service.
Summary of Contents for DX 5000
Page 12: ...10 US Canada 240V Wiring Diagram All wiring is 6 3 plus ground solid copper ...
Page 16: ...14 120V 20A Wiring Diagram GFCI Plug Test Reset For DX 5000 Domestic models ...
Page 17: ...15 For DX 5000 European Models For EX 3000 Domestic Models ...
Page 18: ...16 For LX 4000 and IX 40 Domestic Models For LX 4000 Export Models ...
Page 25: ...23 ...
Page 46: ...44 Notes ...
Page 47: ...45 Notes ...
Page 50: ...48 Notes ...
Page 52: ...5701 E Hillsborough Ave Suite 2450 Tampa FL 33610 5428 727 471 1060 www GulfCoastSpas com ...