8
E l e c t r i c a l S p e c i f i c a t i o n s
Important –
Qualified and licensed electricians must perform all
electrical hookups. The following specifications must be followed in
order to ensure proper performance and safety.
WARNING:
Starting an incorrectly wired spa could cause
severe damage to the mechanical equipment or
even bodily harm. Have your licensed electrician
verify GFCI (or RCD) wiring with the schematics on
pages 9-13 prior to starting the spa or call the
technical support line at (866) 697-4528.
Caution:
Failure to abide by specifications listed may result in
damage to the equipment and will void the warranty.
US/Canada:
All spas must be wired with a properly-sized GFCI breaker (see
table below). Failure to do so will cause equipment damage and
will not be covered under your warranty.
All spas must be protected with an over current protective device
with built-in GFCI in the service panel.
Model
Volts Freq.
Rating
Amps
GFCI
Amps
Wire size
Controller
DX 5000
240/120 60
32
40
6-3 plus ground
VS500Z
DX 5000
(Europe)
220-240 50
1x32
or 2x16
IEE wire
regulation
3 or 5 Wires 4mm²
GS500Z
LX 4000
240
60
40
50
6-3 plus ground
VS501Z
LX 4000
(Europe)
220-240 50
1x32
or 2x16
IEE wire
regulation
3 or 5 Wires 4mm²
GS501Z
EX 3000
120/240 60
16
20
12-3 cord with GFCI plug VS500Z
EX 3000
240/120 60
32
40
6-3 plus ground
VS500Z
IX 40
240
60
40
50
6-3 plus ground
VS501Z
EUROPE:
WARNING:
Disconnect the electrical power before servicing.
Before obtaining access to terminals, all supply
circuits must be disconnected.
Avertissement:
Disconnecter du circuit d'alimentation
electrique avent l'entretien.
Summary of Contents for DX 5000
Page 12: ...10 US Canada 240V Wiring Diagram All wiring is 6 3 plus ground solid copper ...
Page 16: ...14 120V 20A Wiring Diagram GFCI Plug Test Reset For DX 5000 Domestic models ...
Page 17: ...15 For DX 5000 European Models For EX 3000 Domestic Models ...
Page 18: ...16 For LX 4000 and IX 40 Domestic Models For LX 4000 Export Models ...
Page 25: ...23 ...
Page 46: ...44 Notes ...
Page 47: ...45 Notes ...
Page 50: ...48 Notes ...
Page 52: ...5701 E Hillsborough Ave Suite 2450 Tampa FL 33610 5428 727 471 1060 www GulfCoastSpas com ...