4.5 DOOR OPENING WHEN THE EXTERNAL PUSHBUTTON/CONTACT IS OPERATED 

 

This operating mode allows the door to be opened from a remote location without the need to use the monitor or 
telephone in the dwelling; for example, from an external pushbutton or from any electrical/electronic device such as a 
motion detector, smoke or fire detector, etc. The configuration for this is: 
 

 

SWITCH A:

 configured with the 

number of the dwelling 

in which the adaptor is 

installed (in the diagram, dwelling number 5).  If the adaptor is installed in a location 
common to various dwellings, it must be configured with a number different to any of 
them. 

 

 

SWITCH B:

 

switch 3 

must be set

 

in the ON position.  The rest must remain OFF 

 

 

SWITCH C:

 

switches 1 and 5 

must be in the ON position and the rest must be OFF.  

 
 
 

The connections diagram for this operating mode is shown in 

FIGURE 2

 (page 7).

 

 

4.6 ACTIVATION OF VIDEO MONITORING WHEN THE EXTERNAL PUSHBUTTON/CONTACT IS 
OPERATED 

 

This configuration allows the video monitoring to be activated from a remote point without the need to use the monitor 
to see the image from the camera in the street panel in external equipment such as a TV or computer screen. A 
pushbutton or the output from any electrical/electronic device must be connected to the input of the R3660 adaptor. 
When this input is activated, the adaptor will send an order to the street panel to turn on the video monitoring. The 
video signal cabling must lead to the equipment on which the video image is to be seen. The adaptor must be 
configured as follows: 

 

 

SWITCH A: 

configured with the 

number of the dwelling in which the adaptor is 

installed

 (in the diagram, dwelling number 5).  

 

 

SWITCH B: switch 3 

must be

 

in the ON position.  The rest must remain OFF.  

 

 

SWITCH C: switches 1, 4 and 5 

must be set to

 

the ON position and the rest must be 

OFF.  

 

 

 

The connections diagram for this operating mode is shown in 

FIGURE 2

 (page 7).

 

 
4.7 GENERATION OF A CALL TO A DWELLING WHEN THE EXTERNAL PUSHBUTTON/CONTACT IS 
OPERATED 

 

This operating mode is useful to advise a dwelling with a call from a pushbutton or contact external to the entry 
system. Any type of electrical/electronic device may be used, such as motion detectors, smoke and fire detectors, etc. 
It can also be used to advise on the arrival of a visitor via an access without a street panel or for any other type of 
warning, alarms, etc. The adaptor must be configured as follows: 

 

 

SWITCH A: 

configured with the 

number of the dwelling to be called

 (in the 

diagram, dwelling number 5).  

 

 

SWITCH B: switches 3 and 4 

must be in the ON position.  The rest must remain 

OFF.  

 

 

SWITCH C: switch 1 

must be set to

 

the ON position and the rest must be OFF

.  

 
 

 

The connections diagram for this operating mode is shown in 

FIGURE 2

 (page 7).

 

3

SWITCH A

1

2

7

8

6

4

5

1

2

SWITCH B

3

5

6

8

7

1

2

SWITCH C

3

4

5

6

8

7

4

3

SWITCH A

1

2

7

8

6

4

5

1

2

SWITCH B

3

5

6

8

7

1

2

SWITCH C

3

4

5

6

8

7

4

3

SWITCH A

1

2

7

8

6

4

5

1

2

SWITCH B

3

5

6

8

7

1

2

SWITCH C

3

4

5

6

8

7

4

Summary of Contents for R3660

Page 1: ...REV 0 CODE G503155E G503155E MULTI FUNCTION DIGITAL BUS ADAPTOR REF R3660 INSTALLATION GUIDE ...

Page 2: ...he external pushbutton contact is operated 6 4 6 Activation of video monitoring when the external pushbutton contact is operated 6 4 7 Generation of a call to a dwelling when the external pushbutton contact is operated 6 4 8 Generation of a call to the porter s unit when the external pushbutton contact is operated 7 4 9 Immediate door opening on receiving a call from a dwelling 8 4 10 Adjustable e...

Page 3: ...d etc The relay disconnection is user configurable Sending a command over the digital bus so that another device in the installation carries out the requested function video monitoring door opening etc 2 FUNCTIONAL SPECIFICATIONS Physically the adaptor is connected to the digital bus by the terminals called 1M 2M and 3M There are two more terminals for connecting an external pushbutton and three m...

Page 4: ...e R3660 will activate the output relay when it detects a call being made from the street panel defined in the configuration The configuration is SWITCH A configured with the street panel number in the diagram street panel number 1 SWITCH B switches 2 and 3 must be set to the ON position The rest must remain OFF SWITCH C switches 1 2 3 4 and 5 must be set to the OFF position The positions of switch...

Page 5: ...e in the ON position and the rest set to the OFF position The positions of switches 6 7 and 8 define the end of the relay activation see section 5 in this case when the camera is switched off end of communication The connections diagram for this operating mode is shown in FIGURE 1 page 5 FIGURE 1 Connections schematic for the operating modes explained in sections 4 1 4 2 4 3 and 4 4 R3660 BUS 2M C...

Page 6: ...eet panel to turn on the video monitoring The video signal cabling must lead to the equipment on which the video image is to be seen The adaptor must be configured as follows SWITCH A configured with the number of the dwelling in which the adaptor is installed in the diagram dwelling number 5 SWITCH B switch 3 must be in the ON position The rest must remain OFF SWITCH C switches 1 4 and 5 must be ...

Page 7: ... The adaptor must be configured as follows SWITCH A is configured with a number other than those assigned to the dwellings in the installation in the diagram number 5 SWITCH B switch 3 must be in the ON position The rest must remain OFF SWITCH C switches 1 and 4 must be set to the ON position and the rest must be OFF The connections diagram for this operating mode is shown in FIGURE 2 page 7 FIGUR...

Page 8: ...n which the adaptor is installed in the diagram dwelling number 5 It can also be configured with its own number without needing to be associated with a dwelling SWITCH B switches 3 and 4 must be set to the ON position The rest must remain OFF If the adaptor is not associated with any dwelling number configured in switch A switch 5 must be in the ON position main SWITCH C switch 2 must be in the ON...

Page 9: ...etc Vac Vdc Configure switches according to operation mode 4 11 REMOTE OPERATION OF THE RELAY IN A SECOND R3660 ADAPTOR ALARM AND PANIC BUTTON APPLICATIONS This type of configuration is used so that one R3660 adaptor receives an event or activation and orders a second R3660 adaptor to activate its output relay Various adaptors can be installed to form a network all configured with the same number ...

Page 10: ...ITCH B switches 1 2 3 and 4 must be in the ON position The rest must remain OFF This is the receiver mode configuration SWITCH C switches 3 4 and 5 must be set to the ON position and the rest must be OFF The positions of switches 6 7 and 8 define the end of the relay activation see section 5 In the diagram it ends by time in the range 0 to 15 seconds adjustable with the potentiometer FIGURE 5 This...

Page 11: ...hen the adaptor is not associated with a dwelling Switches 6 7 and 8 are not used SWITCH C Switches 1 and 2 define the adaptor s activation mode and response Switches 3 4 and 5 define the type of message that activates or is sent by the adaptor depending on its operation mode Switches 6 7 and 8 are used in those operating modes in which the adaptor s relay is activated Switch 6 defines the relay a...

Page 12: ...d closed with the two screws 8 INSTALLATION STANDARDS The R3630 multi function digital bus adaptor must be used only in Guinaz door and video door opening systems It must be installed as described in this guide complying with the current regulations Only specialised personnel must carry out internal work to it always with the power supply disconnected This device is designed for interior installat...

Reviews: