Malfunction
Cause
Measure
Lubrication system
does not lubricate
No voltage
• Check voltage supply
• Replace battery as per
third-party documenta-
tion
Lubrication lines do
not carry lubricant
Pre-lubrication dis-
tributor / progres-
sive distributor de-
fective
Replace pre-lubrication dis-
tributor / progressive dis-
tributor
Lubrication lines do
not carry lubricant
Output closed and
the headless set
screw is mounted in
the connecting pas-
sage
Remove headless set screw
Lubrication points
are supplied too lit-
tle or not at all
Air in the automatic
lubrication system
Venting the automatic lubri-
cation system
Lubrication points
are supplied too lit-
tle or not at all
Dosage too small
• Adjust lubrication cycle
• If necessary, adjust inter-
mission
Table 7-1
Malfunctions / Troubleshooting
Malfunctions / Troubleshooting
SERVICE MANUAL Automatic lubrication system Memolub