background image

Refuel with engine stopped. Do 
not smoke . 

Biologic / microbiologic hazard 

Oil and fuel leakage is 
detrimental to the environment. 

 

 

 

Other Hazards 

 

Hazard 

Description 

Protective action 

Residual hazard  

Burst in operation 

If the unit is operated on an 
inclined base, lubrication is not 
guaranteed and the unit may 
get  damaged 

Always operate on a flat base . 

 

 

Disposal 

Disposal instructions are given by pictographs on the unit or packaging. For meaning of individual symbols refer to chapter “Symbols 
on Unit”.  

 

Operator Requirement 

The operator shall read the instruction manual carefully before using the unit.  

 

Qualification 

No special qualification is required for use of the unit except for detailed direction by a professional.  

 

Minimum Age 

Only persons above 16 years of age are allowed to work with the unit.   
Exempted from the provision is the use of the juvenile trainees if they work in the course of their professional training with an aim to 
obtain the skill under trainer supervision.  

 

Training 

Use of the unit requires adequate lesson by a professional or the use of the manual only. Special training is not required.  

 

Technical Data  

 

Ordering No..: 

#40631 

Connections 

2 x 230V~50 Hz 

Permanent output 

3500 W/4100 VA 

max. output  

4000 W/4700 VA 

Engine design  

1-Zylinder 4-Takt 

Volume 

270 cm³ 

max output 

6,6 kW/9 PS at 3800 min

-1

 

Fuel/ tank volume 

Benzin/25l 

Noise value indication 

L

WA

 96 dB 

Weight ca 

68 kg 

AVR 

yes 

 

AVR (automatic voltage control) 

 
The voltage automatic control provides for the generator voltage spikes to be within the range of values guaranteed by the power 
supplying company and not to expose the electronic instruments to any risk. 

 

Caution:

 Check before use of the appliance its usability for operation with the generator. 

 
In electronically controlled devices have been previously obtained inquiries by the manufacturer (stereo, computer, TV,  

camcorder, electronic hand tools with stepless regulation or chargers, for example) as a result of the combustion engine generator 
generates a sine wave does not optimal. 
 
Never switch on a second consumer, while another is already in operation. This leads inevitably to fluctuations, which can destroy an 
electronically controlled device. 
 

Transportation and Storage  

 

Caution:

  The unit should be operated in the working position only (flat base) since the fuel or oil could otherwise flow out 

                and the lubrication is not guaranteed any more. 

 

If the battery is employed, it should be taken out before any prolonged out-of-use period and stored at a safe dry 

place (a heated area for example).  

 

Assembly and Initial Operation  

 

Assembly of the wheel undercarriage 

The wheel undercarriage has to be mounted as shown in the picture 1-A. 

14

Summary of Contents for GSE 4700 RS

Page 1: ...GSE 4700 RS 40631 English GB Translation of original operating instructions Generator Güde GmbH Co KG Birkichstrasse 6 D 74549 Wolpertshausen Deutschland ...

Page 2: ...1 8 3 4 5 6 2 7 11 12 13 14 15 A 1 23 2 ...

Page 3: ...nstructions Outfit regular Socket with 230 V 10 A protection pin overloading fuse oil shortage protection A critical point of separate induction appliances is the machine start up input The input may be as much as a treble of nominal capacity This should be always taken into account Scope of Delivery Fig 1 1 Frame 2 2 x 230 V sockets 3 Voltmeter 4 Oil replenishment plug 5 Oil discharge screw 6 eng...

Page 4: ...nnected unit nominal output should be observed Behaviour in case of emergency Provide necessary first aid treatment corresponding to the injury nature and seek qualified medical help as soon as possible Protect the injured person from other injuries and calm him her down First aid kit must always be available in the place of your work in case of accident in accordance with DIN 13164 Material taken...

Page 5: ...eneral regulations and this instruction manual be not observed Residual Hazards and Protective Action Electrical Residual Hazards Hazard Description Protective action Residual Hazard Direct electrical contact Direct contact with wet hands may result in electrical shocks Avoid any contact with wet hands and mind the corresponding ground Thermal Residual Hazards Hazard Description Protective action ...

Page 6: ...A Engine design 1 Zylinder 4 Takt Volume 270 cm max output 6 6 kW 9 PS at 3800 min 1 Fuel tank volume Benzin 25l Noise value indication LWA 96 dB Weight ca 68 kg AVR yes AVR automatic voltage control The voltage automatic control provides for the generator voltage spikes to be within the range of values guaranteed by the power supplying company and not to expose the electronic instruments to any r...

Page 7: ...nstruments and HI FI television sets computers should be connected because of voltage spikes Put the unit on a flat base Do not put it on a metal base Do not expose the unit to strong sunshine and temperatures above 40 C Do not store it in moist ambient conditions Before using it make sure that the input of the appliance to be connected to the unit is lower than the output of the generator Do not ...

Page 8: ...k 4 The ignition plug too distant Ignition plug socket loose wet 5 Ignition plug socket loose 6 Too little oil in the tank 1 Make sure that the fuel cock on off switch are in on position 2 Make sure that there is enough fuel in the tank 3 Pull the starting cable stronger 4 Make sure that the ignition plug is properly mounted 5 Make sure that the ignition plug cable is on the plug Clean the plug an...

Page 9: ... with parts of the filter Unscrew the lid and remove the cover Clean the surface with a wire brush Replace if necessary Inspections and Maintenance Safety Instructions The unit will serve as a sufficient aid only if maintained and cared for appropriately Insufficient maintenance and care may result in accidents and injuries Inspections and Maintenance Schedule Time interval Description Other detai...

Reviews: