22
EN
Technical Data
Welder
MIG 192/6K
Art. No
20076
Degree of protection
IP 21S
Insulation class
H
Rated input voltage (AC Current) U
1
230 V / 400 V
Mains frequency
50 Hz
Protection, time delay
16 A
No-load voltage U
0
36 V
400 V
Load voltage U
2
17,25 V 18,25V 19 V
20,5 V
22 V
Welding current I
2
65 A
85 A
100 A
130 A
160 A
Switch-on time X *
60 %
35%
25 %
15 %
10 %
Regulated section Welding current
65-160 A
Max. input
13,3 kVA
Maximum rated input current I
1max
19,3 A
Maximum effective input current I
1eff
6,5 A
230 V
Load voltage U
2
15,25 V 16 V
17 V
17,5 V
18,5 V
19,75 V
Welding current I
2
25 A
40 A
60 A
70 A
90 A
115 A
Switch-on time X *
100 %
60 %
35%
25 %
15 %
Regulated section Welding current
25-115 A
Max. input
4,5 kVA
Maximum rated input current I
1max
19,8 A
Maximum effective input current I
1eff
8,0 A
Number of switching steps
6
Material thickness
1 - 9 mm
Wire thickness
0,6 - 1,0 mm
Hose package length
3 m
Dimensions L x W x H
710 x 360 x
495 mm
Net/gross weight
36 kg / 41,45
kg
* The ratio of given duration time/the full-cycle time.
Note 1: This ratio shall be within 0~1, and can be indicated by percentage.
Note 2: In this standard, the full-cycle time is 10 min. For example, if the duty cycle is 60 %, the load-applying
time shall be 6 min and the following no-load time shall be 4 min.
Switch-on time determined at 40°C using simulation
ENGLISH