1.6

Technical Specifications

Interfaces

EPS 8112-1

 /

 EPS 8112-2

1 x fixed Mains supply (CEE 7/7 safety plug type E+F,

max.16 A, 230 V, cable length 2m)

6 x Load outputs (IEC C13, max. 10 A)
1 x jack socket (3.5 mm, 3-pole) for external switch

EPS 8112-3

 /

 EPS 8112-4

1 x fixed Mains supply (CEE 7/7 safety plug type E+F,

max.16 A, 230 V, cable length 2m)

6 x Load outputs (CEE 7/3  safety plug, max. 16 A)
1 x jack socket (3.5 mm, 3-pole) for external switch

Environment

·

Operating temperature

·

Storage temperature

·

Humidity

0°C - 50 °C
-20°C - 70 °C
0% - 95% (non-condensing)

Case

powder coated, galvanized steel sheet

Measurements / Weight

EPS 8112-1

 / 

EPS 8112-3

19" (inches), 1 Rack Unit, (Depth 62 mm)
approx. 1.535 kg

EPS 8112-2

 /

 EPS 8112-4

19" (inches), 1 Rack Unit, (Depth 112 mm)
approx. 2.055 kg

SPD according to EN 61643-1 type 3 / class III

 (

EPS 8112-2

 /

 EPS 8112-4

)

 rated voltage U

n

 AC

 230V 50Hz / 60Hz

 max. cont. operating voltage U

c

 AC

 265V 50Hz / 60Hz

 nominal discharge current I

n

 (8/20) us  3 kA

  total discharge current I

total

 (8/20 µ s)  5 kA

Summary of Contents for EPS 8112-1

Page 1: ...Expert Power Sequencer 8112 Series Manual 2021 GUDE Systems GmbH Manual Ver 1 1 0 ...

Page 2: ......

Page 3: ... 1 Security Advice 5 1 2 Content of Delivery 5 1 3 Description 5 1 4 Installation 6 1 4 1 Jack Plug Accessory 7 1 5 block diagram 7 1 6 Technical Specifications 8 2 Operating 10 2 1 Operating the device 11 2 2 Configuration 12 3 Support 14 3 1 Contact 15 3 2 Declaration of Conformity 15 0 Index ...

Page 4: ...Device Description ...

Page 5: ...e or heat is present Because of safety and approval issues it is not allowed to modify the device without our permission Please note the safety advises and manuals of connected devices too The device is NOT a toy It has to be used or stored out or range of children Care about packaging material Plastics has to be stored out of range of children Please recycle the packaging materials In case of fur...

Page 6: ...outine Low power consumption Developed and produced in Germany Additionally for EPS 8112 2 and EPS 8112 4 Integrated overvoltage protection type 3 according to EN61643 1 prevents damage to the device and connected loads Integrated mains filter prevents interference currents and thus eliminates loss of signal quality for connected devices such as loudspeakers amplifiers and beamers 1 4 Installation...

Page 7: ...d by an external switch with cable The Jack Plug Adapter 7960 3 5 mm 3 pole can be purchased as an accessory The jack plug 1 is plugged into the front panel of the EPS 8112 Between 2 and 4 an external potential free switch is connected An possible additionally LED 3 in the switch can be controlled This LED is internally connected to 5V with a 560R resistor 1 5 block diagram This block diagram illu...

Page 8: ...CEE 7 3 safety plug max 16 A 1 x jack socket 3 5 mm 3 pole for external switch Environment Operating temperature Storage temperature Humidity 0 C 50 C 20 C 70 C 0 95 non condensing Case powder coated galvanized steel sheet Measurements Weight EPS 8112 1 EPS 8112 3 19 inches 1 Rack Unit Depth 62 mm approx 1 535 kg EPS 8112 2 EPS 8112 4 19 inches 1 Rack Unit Depth 112 mm approx 2 055 kg SPD accordin...

Page 9: ...ominal load current 16 A voltage protection level Up L N 1 3 kV voltage prot level Up L PE N PE 1 5 kV response time tA L N 25 ns response time tA L N PE 100 ns max backup fuse B 16 A number of ports 1 signaling LED green ok red flashing protection inactive EMC EMI Mains Filter EPS 8112 2 EPS 8112 4 ...

Page 10: ...Operating ...

Page 11: ...switch 1 is only taken into account again at the end of a sequence Operation with optional external switch If a jack plug with switch is plugged into the jack socket 3 the front switch 1 loses its function and the device can only be controlled via the external switch As with the front switch closing the switch starts the switch on sequence when all load outputs are off Opening the external switch ...

Page 12: ...en you switch on and off 2 times Each switch ing operation must be 2 sec After that the LED flashes alternately red green b Please make sure that the ports of the EPS 8112 are switched off so that the pro gramming mode can be started c The programming mode is exited directly when the external connector is plugged in d During programming mode the optional LED for overvoltage protection is not activ...

Page 13: ...be left c Wait 3 sec the LED flashes green X times d If one does nothing for 5 sec then one is out of the programming mode e To set the time switch to On the LED flashes red every second f Switch off after the desired time for N seconds N x flashing g Now the X 1th port is selected switching on continues at b waiting 3 sec contin ues at c The minimum waiting time when switching on is 2 sec and the...

Page 14: ...Support ...

Page 15: ...221 912 90 97 Fax 49 221 912 90 98 E Mail mail gude info Internet www gude info shop gude info Managing Director Dr Ing Michael Gude District Court Köln HRB Nr 17 7 84 WEEE number DE 58173350 Value added tax identification number VAT DE 122778228 3 2 Declaration of Conformity This product from the Expert Power Sequencer 8112 series is in conformity with the European directives for CE marking appli...

Page 16: ...16 Expert Power Sequencer 8112 2021 GUDESystems GmbH Expert Pow er Sequencer 8112 2021 GUDE Systems GmbH 1 20 2021 ...

Reviews: