![GÜDE 72510 Translation Of The Original Instructions Download Page 23](http://html1.mh-extra.com/html/gude-0/72510/72510_translation-of-the-original-instructions_2278009023.webp)
19
GP 800 VF Set
Inspection and maintenance plan
Time interval
Description
Any other details
As needed
Clean the check valve and the prefi lter.
Check the check valve function.
monthly
Check the air pressure in the boiler
When electric consumers open correct to
1,5 - 1,8 bar
8
Failures – causes - removal
Failures
Causes
Removal
Engine does not start
No power supply.
Blocked pump wheel
Turn the engine shaft with screwdri-
ver through the fan cover (to release
friction circles sealing that may be stuck
together).
Pump does not suck
Missing, loose or blocked check valve
Check valve is not in water.
Pump without water
Too high suction head.
Air bubbles in the suction pipeline.
Connections not sealed, pump sucks air,
pump is not deaerated.
Prefi lter clogged
Fix or clean the check valve.
Immerse the check valve into water.
Fill the pump shell with water.
Check the suction head.
Check the tighten of suction pipeline.
Carefully repeat connection according to
the chapter „Connection“!
Clean the prefi lter.
7
Thermal detector swit-
ching the pump off
4
Pump is overheated and switched off by
the thermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have
settled down in the suction hole.
Let the device getting cool!
Check power supply.
Disassemble and clean the suction
hose, prevent from suction of foreign
substances.
Insuffi
cient amount of
water pumped
Too high suction head.
Strainer of the check valve dirty
clogged pre-fi lter
Check the suction head.
Clean the strainer., Position the check valve
lower.
Clean the prefi lter 10
7
Clean the pump and replace worn parts.
(qualifi ed workshop)
Reduced switching
intervals
Air pressure in the receiver too low
Control air pressure.
8
GB
ENGLISH
Summary of Contents for 72510
Page 4: ......
Page 65: ...61 GP800VFSet BG RCD 30mA...
Page 66: ...62 GP800VFSet BG 35 C 0 C 40 C 16 DIN 13164 1 2 3 4 12 24...
Page 67: ...63 GP800VFSet BG www guede com...
Page 68: ...64 GP800VFSet BG 1 5 1 8 8 7 4 7 8...
Page 79: ...75...
Page 80: ...76...
Page 81: ...77...