Failure removal
Failures
Causes
Removal
Engine does not start
No power in the socket
Check the fuse
Defective electric extension cable
Pull the plug out, check it, replace it
Wrong connecting cable
5-wire connection at 2.5 mm2 cross
section
Defective condenser switch
Have the machine checked by a
professional electrician
Wrong engine rotation direction
Wrong connection
Use a screwdriver to turn the phase-
changing switch in the power supply
Splitting knife is not moving
Adjust the two-hand control and
starting levers
Defective control valve - to be
replaced in a service centre only
Splitter has no power
Wrong rotation direction
Have the rotation direction changed
by a professional
Few hydraulic oil
Hydraulic oil to be added
Trigger is bent; hydraulic piston on
the valve is not fully seated
Check all screws on the trigger
Adjust the trigger so that the
hydraulic piston on the valve is fully
seated
Wood has many knobs and the
splitting knife is getting stuck
Lubricate the splitting knife
Control arm is bent
Put the control arm back to the
starting position
The green supply button does not
hold after being pressed
Defective fuse, etc.
Check the cable
2-phase running
Hydraulic pump is whistling, split-
ting knife running jerkily
Oil loss, bottom contamination
Tighten the screws Replace the
hose
Few hydraulic oil
Hydraulic oil to be added
GB