GuardTronic GTWAE7-4D Instruction Download Page 6

 

Installing 

 
 
 
 
 
 
 

 

 

1

 

Untighten the screw to open the unit (see fig.1); 

2

 

Pull in wires through the out-line hole on bottom cover and then connect wire to terminals on PCB according to connection 
line diagram. 

3

 

Fixing the bottom cover on needed position( see fig.2) 

4

 

Link up front cover and tighten the screws(see fig.3) 

 
Sensor emitter LX-AL8 

Jumper setting (like right figure) 

·

Sense  once  to  emit:  after  sensing  once, 

the sensor emit signal   

·

Sense twice to emit: after sensing twice, 

the  sensor  emit  signal  , 

This  setting 

enhance  its  preventing  false-alarm  and 
preventing-pet function

.   

Note:  the  emit  interval  time  is  at  least 
15sec.that  means:  sense  to  make  it  emit, 
after at least 15sec sense it again, it will emit again.   

Test   

·

press the arm key of remote controller or main controller, set the controller to arm.   

·

set the jumper on needed position; 

·

install 9V battery, and install the unit on selected position; 

·

turn on power switch to switch on power, after 60s the sensor enter stable working state;   

·

according to the studying wireless method select study arm zone(2.arm zone) to study LX-AL8; 

·

move along the tangent of the lens, the sense LED light and then it emit signal to controller, the emission LED light. the siren give 

alarm and the controller dial. 

Attention 

·

  Low-battery LED: When battery energy is below 7V, the low-battery LED will flash once a second and remind you replace battery. 

·

  Avoid installing the unit on metal base; 

·

  Avoid installing the unit where sun shine or temperature change obviously, for example: air conditioning, heater etc. 

 
  Door magnetism LX-DM1 

·

  Install magnetism and emitter on upright position of door lock, the distance between them is 3mm~5mm and triangle on emitter 

aim at triangle on magnetism(like right figure); 

·

install DC12V battery into emitter and then close the battery lid; 

·

according to the studying wireless method select study arm zone(2.arm zone) to study LX-DM1; 

·

press the arm key of remote controller or main controller, set the controller to arm.   

·

Open door, the emitter is triggered and its LED light, then emit signal to controller, the siren 

alarm and the controller dial

 

·

tamper design: Under the condition that the triangle on emitter aim at triangle on magnetism, 

when the battery lid is removed, it will emit signal to controller. 

·

Attention: 

 

1

 

Avoid installing the unit on metal base; 

2

 

The magnetism should be on the left of the emitter 
(like following figure) 

 

 
 
 
 
 

Warnning: No slide all numerals of the DIP switch to ON position simultaneously when coding! 

Inco rrect po sition

C o rrect po sition

D o o r

D o o r   f r a m e

D o o r   lo c k

AUTO

DIP switch

Sense LED

Power switch

PIR

Jumper

A

U

T

O

 /

 1

A

U

T

O

 /

 1

1

Emit LED

Sense 
once to 
emit

Sense 
twice to 
emit

Low-battery LED

78

160

out-line hole

Fig. 1

 

Fig. 2

 

Fig. 3

 

Summary of Contents for GTWAE7-4D

Page 1: ...LX AL7 double detectors PIR LX AL11 wired or wireless PIR LX AL9 Function 4 8 arm zone LX HS06 has 4 wired arm zones and 8 wireless arm zones English display Its operation and setting all be displayed by English and operation is more convenient and shortcut Function mightiness Possessing multiple programmable function setting operation and setting is simple standby power for 24 hours One key opera...

Page 2: ... s system password is 000000 all settings and modifying of the controller must be done via system password The user password is 1234 Attention the system password is the highest grade only via it you can modify the user password and all specification of the controller So when you modify the system password you must remember the new password firmly After connection line right switch on power the PO...

Page 3: ...save only the last password please remember new password firmly 2 modify user password user level enter menu 1 level 2 user level LCD display input user level input 4 bit password and press key to confirm The system save only the last password please remember new password firmly code setting center network code 2 code no the setting temporarily report setting3 report Enter menu 3 report LCD displa...

Page 4: ... alarm help alarm separately When select 4 bypass the arm zone do not work setting 3 setup siren alarm time setting1 alert enter menu 1 alert LCD display After inputting press key to confirm is siren s alarm delay can set to 000 999sec factory set to 300sec guard setting2 home enter menu 2 home LCD display After inputting press key to confirm is the arm zone NO guarded When host is at home after h...

Page 5: ...disarm st Home Arm press the Home arm or press HOME key on keypad controller give system arm prompt sound and LCD displays guard st help alarm Remote control press the help alarm key on remote controller controller dial and then the siren alarm controller give help alarm alarm info Keypad operation press and hold MEDICAL FIRE HELP key for 3sec DI DIDI prompt sound will be heard controller dial and...

Page 6: ...LED When battery energy is below 7V the low battery LED will flash once a second and remind you replace battery Avoid installing the unit on metal base Avoid installing the unit where sun shine or temperature change obviously for example air conditioning heater etc Door magnetism LX DM1 Install magnetism and emitter on upright position of door lock the distance between them is 3mm 5mm and triangle...

Reviews: