Guardian Product Return 

Guardian products have been quality tested and are in full working order when shipped from 
the factory, given the rugged nature of these products, shipping is not expected to damage a 
unit. In the unlikely event of a malfunction, Guardian follows the three step procedure below. 

Step I - On-Site Correction 

 

The most common source of difficulties with a new product is improper installation in one of 
two ways: incorrect wiring connections or connection to an incorrect power source. 

 

Product wiring needs to be properly connected to the on-site wiring. Correct wiring 
instructions are shown in the user manual included with the product. 

 

Connecting a telephone to a standard power source, rather than tip & ring, will blow the 
telephone’s internal, user-replaceable fuse. In the event of fuse burn-out, disconnect the 
telephone from the power source, replace the fuse, and reconnect following the wiring 
diagrams provided with the product. 

Step II - Return Materials Authorization (RMA) 

 

When a product has been installed following user manual instructions, and the unit fails to 
operate, the user must contact Guardian Telecom to obtain authorization to return the 
product.  This can be done by completing a RMA form online at 
www.guardiantelecom.com, or by calling the service telephone number given in this 
manual. 

 

After providing information on the product, the owner and the nature of the problem, 
Guardian will issue a RMA number, to be shown on documentation returned with the 
product. 

 

In addition to the RMA number, shipping documents should include name, address and 
telephone number of the owner along with contact information for the person responsible 
for the repair and/or the user who identified the malfunction. 

 

(Where a product is being returned for repair from outside of Canada, customs 
documentation must show the product’s serial number, date of export [date of purchase], 
and a notation that the equipment is: “Canadian goods returning.”) 

Step III - Factory Authorized Service 

 

Once received, each product is carefully inspected and tested. If the product is under 
warranty, repairs are completed and the product returned to the owner, generally within 
five working days of receipt by the factory. 

 

A product that has been subjected to misuse, neglect or accident or is beyond the warranty 
period will be evaluated. The service department will provide the owner’s representative 
with a repair cost estimate. Once approved, repairs are completed and the product 
returned, generally within five working days. 

 

 

Summary of Contents for HR60

Page 1: ...Calgary Alberta Canada T2E 8W1 Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com Industrial Communications Worldwide Industrial Telephone Model HR60 Installation Operation P002781 Rev E 11 23 2004 10 05 ...

Page 2: ... 8 Disclaimer 8 Warning 8 Service Telephone Number 8 Feedback 8 Guardian Product Return 9 Table of Figures Figure 1 Mounting 4 Figure 2 Dimensions 4 Figure 3 Internal Layout Wiring 4 Package Contents 1 HR60 Telephone 1 Installation Operation Manual HR60 Models and Options P6260 Standard telephone with 7 8 Knock out P6264 Standard telephone with NPT conduit hub Accessories P7225 Weatherproof ring d...

Page 3: ... and powder coated Keypad durable standard 3 x 4 keypad Hook Switch magnetic reed hook switch no moving parts Surge Arrestor prevents damage to the electronic circuits in the event of a high voltage spike on the telephone line Noise Reducing Microphone aids in clarity of transmission in noisy areas Tone DTMF Operation factory set to tone DTMF dialing pulse dialing can be ordered or configured in t...

Page 4: ...l HR60 Page 4 9 0 229mm 5 0 127mm 5 1 130mm 2 2 56mm 2 7 69mm 6 4 163mm for 10 or M5 Figure 1 Mounting Figure 2 Dimensions Figure 3 Internal Layout Wiring HOUSING TIP RING GROUND RINGER TONE PULSE JUMPER 1 4A 250V FUSE TERMINAL STRIP SURGE ARRESTOR HS HK ...

Page 5: ... faceplate the circuit board is on the faceplate Secure the unit to the wall Tip Use 10 or M5 screws to secure the unit to the wall For Model P6260 with a 7 8 entry hole install a suitable grommet or hub and bring cable into the enclosure through the entrance Attach individual wires from the exchange Tip Ring Ground to the terminal strip Tip Ring are not polarity sensitive If a conduit hub is used...

Page 6: ...s drive faceplate screws remove the faceplate and unplug the harness Replace the fuse or handset or change the tone pulse setting as required Note Be careful when removing the faceplate the circuit board is on the faceplate Note Replace the fuse only with a 0 25 amp 2AG fast blow Failure to do so will void warranty If on reconnecting power the fuse fails check the telephone system wiring The fuse ...

Page 7: ...HZ LINE VOLTAGE 24 56 VDC LOOP CURRENT 20 120 mA CONNECTION METHOD TERMINAL STRIP FUSE 0 25 AMP 2AG FAST BLOW Environmental TEMPERATURE 40O TO 60O C 40O TO 140O F HUMIDITY 0 TO 95 RH NON CONDENSING DUSTPROOF FULLY GASKETTED ENCLOSURE Mechanical HOOK SWITCH CRADLE SWITCH LIFE 1 000 000 OPERATIONS BODY CONSTRUCTION 14 GA STEEL ZINC DICHROMATE PLATED POWDER COATED DIMENSIONS 229 X 127 X 130 MM 9 X 5 ...

Page 8: ...ing fuses only this device may be opened and reassembled by qualified personnel following the instructions in the product manual Service Telephone Number 1 800 363 8010 Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone number between regular busin...

Page 9: ...rdian Telecom to obtain authorization to return the product This can be done by completing a RMA form online at www guardiantelecom com or by calling the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product In addition to the RMA number...

Page 10: ...Guardian Telecom Inc Installation and Operation Model HR60 Page 10 Notes Model No Part No Serial No Date of Purchase ...

Page 11: ......

Page 12: ...2 10th Street N E Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Industrial Communications Worldwide Guardian Telecom Inc 2004 ...

Reviews: