background image

 G

uar

di

an

 F

al

l P

ro

te

ct

io

 63

05

 S

. 2

31

st 

St

., 

Ken

t, 

W

A

 9

80

32 

 

7

Labels

6305 S. 231s

t St.

Ken

t, W

A 98032

Phone: (800) 466-6385

Fax

: (800) 670-7892

www.guar

dianfal

l.com

6305 S. 231st St.

Kent, WA 98032

Phone: (800) 466-6385

Fax: (800) 670-7892

www.guardianfall.com

DO NO

T REM

O

VE LABEL

If equipmen

t f

ails inspection

IMMEDIA

TEL

Y REM

O

VE FR

O

M SERVICE

User must inspect prior to EACH use. Competent Person must complete
formal inspection every 6 months. Competent Person to inspect and initial.

INSPE

CTION GRID

Date of First Use: __________________. 

Product lifetime is indefinite as

long as equipment passes pre-use and Competent Person inspections.

YR

J

F

M A

M

J

J

A

S

O

N

D

20____

20____

20____
20____

20____

!

CAUTION

Instruction cards MUST ALWAYS remain attached to EACH

6’/8’/10’/12’ G-Rail. DO NOT USE if instruction cards are
not present. PRIOR TO USE, read and fully understand all

instructions included with the equipment at time of shipment

from the manufacturer. All users must be fully trained with the

instructions for proper use of G-Rail Systems. 

Distributed by Engineered Fall Protection  |  [email protected]  |  (314) 492-4422  |  www.EngineeredFallProtection.com

Summary of Contents for G-Rail

Page 1: ...ctions Read and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 2 Componen...

Page 2: ...d associated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited de...

Page 3: ...any connections to guardrail systems WARNING NEVER lean or climb on guardrail systems WARNING Fall Prevention G Rails may be used in Fall Prevention applications ONLY Fall Prevention Systems are plac...

Page 4: ...ge of the guardrail system and the working level not the toeboard All intermediary rails not the toprail or the midrail must not allow for gaps greater than 19 Toeboards are REQUIRED on roofs of slope...

Page 5: ...YS use outriggers at BOTH ends of any interruption in continuous guardrail sections and at BOTH ends of a continuous guardrail section An outrigger is a guardrail installed perpendicular to a continuo...

Page 6: ...king and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a...

Page 7: ...st falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap h...

Page 8: ...N GRID Date of First Use __________________ Product lifetime is indefinite as long as equipment passes pre use and Competent Person inspections YR J F M A M J J A S O N D 20____ 20____ 20____ 20____ 2...

Reviews: