About the Photo Eye Safety System 

The Photo Eye Safety System provides  protection  against      
entrapment while the door is closing. When properly connected 
and aligned, the emitter Photo Eye emits an invisible infrared 
light beam while the Sensor Photo Eye monitors that beam.  

If the beam is obstructed during door-closing, the entrapment 
protection will be triggered and the door will stop and reverse to 
the open position. The courtesy light will flash for 30 seconds 
indicating an obstruction.

 

Installing The Photo Eye Safety System 

Wall-mounting 

1. 

Place the Photo Eyes facing each other on each side of 
the garage door.  Position the sensors so they are no 
higher than 6” (15cm) above the floor, as shown in Fig.1.  

2. 

Drill 3/16” holes using the mounting holes on the Bracket 
as a template. Secure with #12 x 1” Lag Screws 

 

(provided).  

3. 

If necessary use the Optional Wall-mount Position (Fig.1) 
to better fit your door-track and improve obstacle 

 

 

 

 

 

avoidance. To adjust the position, loosen the wing nut, 
disassemble the Bracket and move the Photo Eye to the 
lower position on the holder. 

4. 

If necessary, align the Photo Eyes by loosening the wing 
nut . (This step may be further required in 

Aligning the 

Photo Eye Safety System 

on page 16.) 

Alternative Floor-mounting 

1. 

Place the Photo Eyes facing each other on each side of 
the garage door, as shown in Fig.2. 

2.  If attaching to concrete, secure the photo eyes using    

concrete anchors and bolts (not provided). 

3. 

If necessary, align the Photo Eyes by loosening the wing 
nut. (This step may be further required in 

Aligning the 

Photo Eye Safety System 

on page 16.) 

To Connect Photo Eye Safety System

 

1. 

Connect a pair of wires from either one of the Photo Eyes 
to a pair of “PHOTO EYE” terminals on the rear of the 
Opener as shown in Fig. 3.  Refer to 

Wiring Instructions

 

on page 13 for proper connections. 

2. 

Repeat above step to connect the other Photo Eye. 

3. Refer 

to 

Wiring Instructions

 on page 13 to ensure wires 

are connected properly. 

WARNING 

To prevent SERIOUS INJURY or DEATH from electrocution: 

- Power MUST NOT be connected BEFORE Photo Eye Safety system is connected and aligned. 

- The Opener will not operate until the Photo Eye Safety System is properly connected and aligned. 

- Install the Photo Eyes NO higher than 6” (15cm) above the floor. 

No part of garage door or other objects should obstruct the Photo Eye Safety System during door-closing.

 

#12 x 1” 
Lag Screw 

Loosen

 

Inside 
Garage

 

Door Track

 

Door Track

 

Inside 
Garage

 

6” max. above floor

 

Alignment

 

Alignment

 

Fig. 1 (Wall Mount)

 

Fig. 2 (Floor Mount)

 

Fig. 3

 

6” max.

 

Optional 
wall mount 
position

 

Inside 
Garage

 

From one of 
the Photo Eye

 

From the 
other one

 

Connecting Photo Eye Safety System  

Summary of Contents for DCS 3/4HP

Page 1: ...ILL NOT CLOSE until the Photo Eye Safety System is properly installed and aligned REGULARLY CHECK and TEST the Opener according to the safety label to ENSURE SAFE OPERATION Retain this manual for futu...

Page 2: ...3 Connecting Photo Eye Safety System 14 Connecting Wall Panel 15 Connecting Power 16 Adjustment Aligning the Photo Eye Safety System 16 Travel Limit Adjustment UP Limit 17 Travel Limit Adjustment DOWN...

Page 3: ...ents x3 Hanging Brackets x 2 Self Threading Screw 1 4 x 5 8 Door Bracket Rail End Segment with Trolley Stop Bolt Clevis Pin Door arms 5 16 x 1 Clevis Pin Header Bracket 5 16 x 1 1 2 Pulley Trolley Sha...

Page 4: ...ent SERIOUS INJURY or DEATH Before beginning installation of the Opener please complete the following test to ensure that your door is balanced and in good working condition A poorly balanced door can...

Page 5: ...SERIOUS INJURY DO NOT connect power until instructed Keep hands and fingers clear from sprocket during operation Wear gloves when installing chain belt and cable Keep hands and fingers away from join...

Page 6: ...heard when they are connected and locked as shown in Fig 3 To Link Cable with Chain Refer to Fig 4 Place the chain carton beside the rail hold the Chain to Cable Connector and pull about 8 20cm of ch...

Page 7: ...Installing the Chain 1 Master Link Link Cap Spring Clip Cable Eyelet 2 Open end of chain Base of Rail 1 4 6mm Mid point of rail assembly Chain Top of Rail Actual Size x 1 THE SPROCKET COVER MUST BE SE...

Page 8: ...ling as shown in Fig 3 Center the Header Bracket on the vertical mark no more than 6 15cm from the header wall Mark and drill holes to fasten the Header Bracket securely to a structural support Fig 1...

Page 9: ...nt bracket with this option skip this step and proceed with the next step Mounting Opener to Ceiling 1 Position the Door Bracket on the centerline of the door approximately 2 4 5 10cm below the top ed...

Page 10: ...ing Brackets to the structural supports using 5 16 x1 2 Lag Screws provided 7 Secure the Opener to the Hanging Brackets and secure each side with a 5 16 x 1 Bolt and Flange Nut provided 8 Move the doo...

Page 11: ...1 Straight Door Arm Curved Door Arm Attaching Door Arms NOTE The trolley must be a minimum of 8 20cm away from the pulley To Connect Door Arm Follow the steps shown in Fig 1 1 Fasten the Straight Door...

Page 12: ...To prevent SERIOUS INJURY or DEATH from a falling garage door In case of power failure or door obstruction PULL EMERGENCY HANDLE to release door from Opener When Emergency Release is in the released...

Page 13: ...iped wire non polarized from the SAME accessory as shown in Fig 2 5 Check for proper connection by gently pulling on the wire The wire should not come out of the terminal NO exposed part of the wire s...

Page 14: ...ernative Floor mounting 1 Place the Photo Eyes facing each other on each side of the garage door as shown in Fig 2 2 If attaching to concrete secure the photo eyes using concrete anchors and bolts not...

Page 15: ...inside your garage To install the Wall Panel 1 Inside your garage install the back plate of the Wall Panel within sight of the door at a minimum height of 5 feet 1 5m off the ground Ensure it is insta...

Page 16: ...The Photo Eye Safety System MUST be installed BEFORE connecting power The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener Connecting Power For Permanent Wiri...

Page 17: ...P DOWN FORCE LIMIT UP DOWN OK 1 2 3 4 About Travel Limit Adjustment Limit Adjustments regulate the fully open UP limit position and fully closed DOWN limit position at which the door will stop when op...

Page 18: ...P DOWN FORCE LIMIT UP DOWN OK x2 UP DOWN FORCE LIMIT UP DOWN Travel Limit Adjustment II DOWN Limit x1 1 2 3 CAUTION WHILE PRESSING THE DOWN LIMIT BUTTON CAREFULLY WATCH DOOR TRAVEL DISTANCE RELEASE BU...

Page 19: ...Force Auto Adjustment Following limit setting the unit is now ready to automatically adjust the forces for opening and closing the door Proceed with the following steps to complete adjustment 1 With...

Page 20: ...the fully opened position 5 The Safety Reverse System works properly and the opener is ready to use If the door just stops on the object adjust the Opener as follows The close travel maybe inadequate...

Page 21: ...keypad codes can be added to the unit by repeating the above procedures If more than 20 Transmitters are stored the first stored Transmitter will be replaced i e the 21st Transmitter replaces the 1st...

Page 22: ...d in good working condition Emergency Release Knob Photo Eye Safety System Invisible Light Beam Actual Operating Scenario Wall Panel Operating the Opener Controls Operation Wall Panel Indoor Momentary...

Page 23: ...ull to Disconnect Flip to reconnect Manual Operation Door status Activation using Wall Panel Transmitter Door at fully open close position Door will move to fully close open position Door is closing D...

Page 24: ...oes not turn on Replace light bulb A19 incandescent Max 100W The courtesy light does not turn off Defective Logic Board The Opener hums as the Trolley hits the Trolley Stop Bolt in open travel 1 Make...

Page 25: ...11 24908 Chain Item Part No Name Description 1 24919 Header Bracket 2 24917 Door Bracket 3 24925 Hardware Bag Installation hardware shown on P 3 4 24923 Curved Door Arm 5 24921 Straight Door Arm 6 24...

Page 26: ...nsformer 3 Logic Board 4 Position Encoder 5 DC Motor 6 24981 Cover plate Front 7 24982 Cover plate Back 8 24980 Opener Cover 9 Lamp Plate 10 24905 Lamp Dome Should be replaced by qualified technician...

Page 27: ...t itself ii To any additional damage or deterioration arising from attributable to the operation of the Operator after it is known to be defective 9 Exclusions to Warranty Period i Repair or Warranty...