Guardian Fall Protection recommends that a back-up fall protection

system, functional in Fall Arrest applications, be used in conjunction

with all Rebar Chain Assemblies. Competent Person must make final

determination regarding use of back-up fall protection system.

!

WARNING

1. Connect back-up fall protection system, deemed compatible by a Competent Person, to harness dorsal
D-ring. Follow all manufacturer’s instructions for all components of back-up system. Ensure sufficient fall
clearance exists at all work areas, and that all applicable safety regulations are followed at all times.

Quick Link Carabiners must only be used to connect Rebar Chain

Assembly chain links for purposes of adjusting length of chain.

Both Chain Legs must always be adjusted to same length.

NEVER make any connections to Quick Link Carabiners.

!

WARNING

Connect Snap Hooks

to harness shoulder

OR side D-rings.

Rebar Hook fully

closed and

locked around

structural rebar.

3. Connect Rebar Hook to structural rebar; ensure hook fully closes and locks around rebar. If climbing, ensure
that 100% tie-off is maintained at all times.

2. If applicable/necessary, adjust length of Chain Legs by using Quick Link Carabiners to connect chain links.
NEVER cross-connect Chain Legs. Then, connect Rebar Chain Assembly Snap Hooks to harness side D-rings OR
harness shoulder D-rings. Ensure Snap Hooks fully close and lock around D-rings. MAXIMUM 1 connection per
D-ring.

01600

01605

01608

01609

01610

01611

01603

21610

Summary of Contents for 01600

Page 1: ...ctions Read and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 2 Limitations 2 3 Components and Specifications 3 4 Maintenance Cleaning and Storage 5 Inspection 5 Installation and Use 4 Inspection Log 5 Labels 7 ...

Page 2: ...rest systems and associated components Worker Classifications CAUTION Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree or certification and with extensive experience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and resc...

Page 3: ...ll protection system suitable for Fall Arrest applications be used in conjunction with Rebar Chain Assemblies Worker capacity range including all clothing tools and equipment 130 310 lbs NEVER use Rebar Chain Assemblies for rigging equipment or as material hoists FALL CLEARANCE CALCULATION Lanyard length 6 total Safety factor 3 total Deceleration distance 4 total Height of harness dorsal D ring fr...

Page 4: ...e all possibility of roll out Roll out occurs when interference between a hook and the attachment point causes the hook gate to unintentionally open and release All connections must be selected and deemed compatible with Rebar Chain Assembly by a Competent Person All connector gates must be self closing and self locking and withstand minimum loads of 3 600 lbs See the following for examples of com...

Page 5: ...followed at all times Quick Link Carabiners must only be used to connect Rebar Chain Assembly chain links for purposes of adjusting length of chain Both Chain Legs must always be adjusted to same length NEVER make any connections to Quick Link Carabiners WARNING Connect Snap Hooks to harness shoulder OR side D rings Rebar Hook fully closed and locked around structural rebar 3 Connect Rebar Hook to...

Page 6: ... debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a Competent Person other than the user must inspect Rebar Chain Assembly Competent Person inspections MUST be recorded in inspection log in instruction manual and on equipment...

Page 7: ...n LE SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap hooks carabiners and other connectors must be selected and applied in a compatible fashion All risk of disengagement must be eliminated All snap hooks and carabiners mus...

Page 8: ...A S O N D YR Rebar Chain Assembly Prior to use read and understand all manufacturer s instructions Remove from service if exposed to forces of fall arrest For Work Positioning applications ONLY MAXIMUM free fall 2 Date of Manufacture Weight capacity range including equipment 130 310 lbs Material galvanized steel Avoid contact with sharp and abrasive edges and surfaces ANSI Z359 1 07 and A10 32 12 ...

Reviews: