Overview 

Talk Back System EXP-TBA 

The model EXP-TBA is an intercom system designed for use in situations where frequent 
communication between two stations is required. The system is particularly well suited to 
drilling rig operations.  The system utilizes a remote Slave loudspeaker in dual roles, to 
broadcast messages from the Master Station and to act as a microphone to pick up and 
transmit messages back to the Master Station.  The Master Station has a microphone on the 
faceplate which is activated when the Push-To-Page button on the faceplate is pressed.  An 
option is for the connection of a remote foot switch or hand operated button switch, which 
when activated will cause the Master Station loudspeaker to act as a microphone. 

The EXP-TBA system has two possible operating modes: 

1. 

Hands Free Talk-Back Mode:

 In this mode the Slave speaker is always configured 

as a microphone sending any sound in the area back to the Master Station speaker, 
except when the Master Station is activated to transmit.  If desired a push button can 
be installed near the Slave speaker, which when pressed will cause a ringing signal 
to be heard over the Master Station speaker.  The ringing signal will be heard even if 
the Master Station speaker volume is turned down. 

2. 

Push-To-Talk Mode:

 In this mode neither the Master Station speaker nor the Slave 

speaker is normally in transmit mode.  A push button is required at the Slave speaker 
to put the speaker into transmit mode.  The button must be held in for the duration of 
the call. 

 

EXP-TBA Features 

Enclosure and Faceplate 

  copper free cast aluminum - powder coated 

Master/Slave Operation 

  only one master station required 

Post Announcement Tone 

  optional – jumper on circuit board 

Slave Operator Ring Tone To Master Station 

  optional – requires a push button switch at the slave speaker location 

  ring tone volume adjustable (internal) 

Page Switch 

  page switch on faceplate of enclosure 

  option for external hand or foot switch 

Master Microphone 

  on faceplate of master station 

  option for use of master speaker as microphone 

Controls 

  separate master and slave speaker volume controls on faceplate 

Power Requirement 

  24 VDC or 24/120/230 VAC 

Summary of Contents for ExP-TBA

Page 1: ...Canada T2E 8W1 Industrial Communications Worldwide Explosion Proof Talk Back Wall Station Model ExP TBA Installation Operation P005615 Rev E 080220 2 21 2008 1 43 PM Ph 403 258 3100 email info guardia...

Page 2: ...ineering Specifications 10 Warranty 11 Disclaimer 11 Warning 11 Service Telephone Number 11 Feedback 11 Guardian Product Return 12 Table of Figures Figure 1 Features 4 Figure 2 Dimensions 4 Figure 3 M...

Page 3: ...er except when the Master Station is activated to transmit If desired a push button can be installed near the Slave speaker which when pressed will cause a ringing signal to be heard over the Master S...

Page 4: ...STER SPEAKER 1 NPT CONNECTOR FOR SPEAKER ENTRANCE VOLUME CONTROL BUTTON PUSH TO TALK SLAVE SPEAKER STATION MICROPHONE ID LABEL CERTIFICATION LABEL WARNING LABEL CAST ALUMINUM ENCLOSURE WITH POWDERCOAT...

Page 5: ...e 4 Typical Installation Page 5 14 67 373mm 7 25 184mm 0 4 10mm 4 PLACES POWER SUPPLY 24VDC 120 240VAC OPTIONAL REMOTE HAND FOOT SWITCH MASTER STATION SPEAKER MASTER STATION E O V M L U R A M E S T O...

Page 6: ...the post announcement tone set the jumper to the TONE position to disable the tone set the jumper to the OFF position Microphone input level Potentiometer This potentiometer is referenced R24 and labe...

Page 7: ...lk Back Mode In Hands Free Talk Back mode the Master Station speaker is normally on and the Slave speaker is functioning as a microphone Faceplate Push To Page switch Without any switches activated an...

Page 8: ...hone The Slave speaker is turned on to broadcast the message sent from the Master Station The Slave Station Switch When the Slave station switch is pressed the Slave speaker is converted into a microp...

Page 9: ...EN T R 54 1 J3 D ETA IL B N eutral G round H ot 2 3 1 J7 D ETAIL C 4 5 2 3 J7 D E TAIL C FR O M LA R G E TR AN S FO R M ER TR C 255 C 12 TE R M IN A LS IN P U T A D JU STM EN T R 24 M IC IN P U T A D...

Page 10: ...T SPST SWITCH AUDIO OUTPUTS MASTER SPEAKER CHANNEL 70V LINE 10 WRMS SLAVE SPEAKER CHANNEL 70V LINE 10 WRMS ENVIRONMENTAL TEMPERATURE 40 TO 60 C 40 TO 140 F HUMIDITY 0 95 RH NON CONDENSING MECHANICAL B...

Page 11: ...equential damages Warning High voltages may be present in this product Ensure that power is removed before installing performing maintenance or repairs Service Telephone Number 1 800 363 8010 North Am...

Page 12: ...ardian Telecom to obtain authorization to return the product This can be done by completing a RMA form online at www guardiantelecom com or by calling the service telephone number given in this manual...

Page 13: ...Guardian Telecom Inc Installation and Operation Model ExP TBA Page 13 Notes Model No Part No Serial No Date of Purchase...

Page 14: ......

Page 15: ......

Page 16: ...N E Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Click to open message box Industrial Communication...

Reviews: