Unit Operation 

 

Normal Operation 

 

  The AS12 detects amplifier failure by comparing logic input through the 

absence of an output signal. 

 

LED Indicators 

 

  When an amplifier goes into a fault condition, the corresponding amplifier 

status indicator LED on the front of the AS12 illuminates. 

See: Front Panel 
drawing.  

o

  the upper LED illuminates to show a history of amplifier failure and stays 

lit until the reset button is pressed. 

 

o

  the lower LED stays illuminated as long as the amplifier is in a fault 

condition. 

 

  If the standby amplifier goes into a fault condition, the lower Standby LED 

illuminates and the upper LED will record the history. 

 

Standby Failure 

 

  If a problem is external to the amplifier when the primary amplifier fails the 

standby amplifier will also fail. 

Multiple Amplifier Failure 

  If more than one amplifier fails at the same time, the standby amplifier will 

only replace the highest priority (the lowest numbered) amplifier. 

Tip: Certain problems 
external to an amplifier 
on the paging zone(s) 
may case the primary 
amplifier to fail. 

Reset LED History  

 

  After identifying and correcting an amplifier fault, press the reset button to 

clear LED history indicators. 

 

Setting VOX Threshold Adjustments 

 

  The VOX threshold adjustment is used to compare with the Logic VOX 

input from a device such as DA388 or a TOA automatic Microphone 
Mixer VOX logic output to determine the presence of a valid audio output 
from the amplifier. 

 

  With a variable signal input to the DA388, raise the level until the VOX 

logic signal is just activated. 

 

  Turn the VOX Threshold adjustment to minimum and the event LED will 

be illuminated. 

 

  Adjust the Threshold level until the event LED extinguishes. 

 

  Repeat the process for all channels. 

 

 
 

Summary of Contents for AS12

Page 1: ...e Automatic Amplifier Switch Model AS12 Installation and Operation VOX THRESHOLD ADJUSTMENT AMP 1 AMP 2 AMP 3 AMP 4 STAND BY AS 12 AMPLIFIER SWITCH RESET Guardian Telecom Inc P005093 Rev C 070518 7 21...

Page 2: ...mer 10 Warning 10 Service Telephone Number 10 Feedback 10 Guardian Product Return 11 Table of Figures Figure 1 Dimensions 4 Figure 2 Front Panel 4 Figure 3 Rear Panel 5 Figure 4 Block Diagram 6 Figure...

Page 3: ...integrated industrial emergency communications system the AS12 ensures uninterrupted communication in the event of an amplifier failure The AS12 Automatic Amplifier Switch is one component in Guardia...

Page 4: ...r LED See below 3 Fault History Reset Button 4 VOX Threshold Adjustments 5 Backup Threshold Adjustment 6 Backup Amplifier Status Indicator LED See below There are two Status Indicators The top one ind...

Page 5: ...MP 4 FROM BACKUP AMP 1 2 3 4 5 C 1 2 3 4 5 C 220 VAC FUSE 1 A POWER CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 1 2 3 9 8 4 Figure 3 Rear Panel 1 Power ON OFF Switch 2 Fuse 1 Amp 3 Power input for 120 230...

Page 6: ...CHANNEL AUDIO OUTPUTS LOGIC INPUTS CHANNEL PRE AMP ACTIVE ALLOCATOR BACKUP CHANNEL DETECTOR FAIL CHANNEL CONTROL UNIT CH SB CH 4 CH 3 CH 2 CH 1 CH 4 CH 3 CH 2 CH 1 Figure 4 Block Diagram DA388 MIC 1...

Page 7: ...connected to the AS12 are turned off Follow all appropriate electrical codes for the installation Use the following sequence when wiring connections o Audio Inputs See Connection Details below o Cont...

Page 8: ...fails the standby amplifier will also fail Multiple Amplifier Failure If more than one amplifier fails at the same time the standby amplifier will only replace the highest priority the lowest numbered...

Page 9: ...Inputs 5V TTL LEVEL RECOMMENDED ACTIVATING DEVICES DRY CONTACT RELAY MINIMUM OPEN COLLECTOR OPEN DRAIN CURRENT CAPACITY 100mA Logic Outputs 4 Logic Open Drain Outputs OUTPUT SWITCH CURRENT CAPACITY 4...

Page 10: ...rnal components the only maintenance possible is the replacement of the fuse which is available from the back panel Service Telephone Number 1 800 363 8010 Guardian Telecom provides a customer service...

Page 11: ...ng the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation re...

Page 12: ...Calgary Alberta Canada T2E 8W1 Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box Industrial Communicat...

Reviews: