Installation and Operation 

Model AG17 

 

Rear Panel  

The rear panel of the AG17 is where all the connections are made.  

1. Clear/Reset 

Terminals   

Connect Clear and Reset switches. 

2.  Alarm Logic Outputs 

 

 

Trigger external devices. 

3.  Audio / Logic Output 

Connect external devices. 

4.  Output Volume Control   

Adjusts overall audio output level of 
the AG17. 

5.  Input Volume Control 

 

 

Adjusts input level of the Override 
Audio Signal. 

6.  Override Audio / Logic 

Input 

Overrides tones when the logic 
signal is present. 

7. Programming 

Jack 

 

Connects a DTMF tone generating 
analog telephone for programming 
the AG17. 

8.  Alarm Logic Inputs 

 

 

Activate any of 8 available alarm 
tones. 

9. Relay 

Contacts 

(Optional)  

Trigger external devices. 

10. Fuse 

 

Fuse replacement with 1/2A, 3AG, 
250V fast blow fuse only. 

11. Power On/Off 

 

Switches unit on or off. 

 
 

 

Figure 2 - Rear Panel 

 

3

ALARM LOGIC OUT

GUARDIAN TELECOM INC.
CALGARY, ALBERTA, CANADA

+

-

+

2

1

-

RESET

CLEAR

E

F

INPUT / OUTPUT

2

C

8

7

5 6

C

4

-

+

+ -

+ -

-

+

1

C

C

5

4

6 7 8

3

L

LOGIC

AUDIO

A

120VAC

FUSE 1/2A

FU

SE

ALARM LOGIC IN

7

5

6

3

4

2

1

VOLUME

A B C

A

B

A

C

A B

C

O/P

L

A

OUTPUT

C

C

A B

A

C

B

A

C

B

B

A

L

INPUT

I/P

ALARM RELAY CONTACTS

8

RELAY CONTACTS

C

B C

A

B

A

NORMALLY CLOSED

NORMALLY OPEN

COMMON

S

U

POWER

 

 

Page 5 

 

 

Summary of Contents for AG17

Page 1: ...Alarm Tone Generator Model AG17 Installation Operation P005089 Rev C 150930 9 30 2015 12 25 PM Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com ...

Page 2: ... Terminals Rear Panel Remote 10 Relay Contacts Optional 10 Programming the AG17 11 Setting Input Channel Alarm Tones 11 Setting Triggering and Attenuation 12 Setting the Timer for Pulse Triggered Logic Inputs 13 Setting the All Clear Tone 13 Interpreting the LED Display Pattern Table 13 Displaying All Parameters Stored In Non Volatile RAM 14 Product Specifications 15 Warranty 17 Disclaimer 17 Warn...

Page 3: ...Generator is one component in Guardian Telecom s full line of paging system products which include amplifiers and signal and switch conditioning equipment AG17 Tone Generator Models Model P5970 AG17 Model P5960 AG17 with optional relay board Features Programmable 10 tone alarm library user programmable microprocessor to customize tone priority duration triggering muting and attenuation eight chann...

Page 4: ...el LED Indicators Clear and Reset Switches 1 Power LED Illuminates when the unit is on 2 Alarm LEDs Illuminates when the alarm is active 3 Clear Switch Activates the 3 Beep Clear tone 4 Reset Switch Turns off the highest priority tone active Figure 1 Front Panel Page 4 ...

Page 5: ... Programming Jack Connects a DTMF tone generating analog telephone for programming the AG17 8 Alarm Logic Inputs Activate any of 8 available alarm tones 9 Relay Contacts Optional Trigger external devices 10 Fuse Fuse replacement with 1 2A 3AG 250V fast blow fuse only 11 Power On Off Switches unit on or off Figure 2 Rear Panel 3 ALARM LOGIC OUT GUARDIAN TELECOM INC CALGARY ALBERTA CANADA 2 1 RESET ...

Page 6: ...LOSED INPUT OUTPUT L A RELAY CONTACTS NORMALLY OPEN COMMON AG 17 Alarm Tone Generator RESET INPUT Audio Pair ALARM LOGIC OUT 1 5 3 2 4 7 6 8 C C OUTPUT A L I P VOLUME O P A Logic Pair ALARM LOGIC IN L 1 2 3 4 5 C 6 7 8 C ALARM RELAY CONTACTS B A C 1 C A B A B 2 3 B C A C A 4 C A C B B C 5 6 B A C A B 7 8 C B A Fire Gas Alarm System Manual Push Button Alarm Activation F FUSE 1 2A E LOGIC AUDIO 120V...

Page 7: ...AG17 unit There are no user serviceable parts inside the unit Tip Unauthorized modifications void the product warranty Choose a location on a standard 19 equipment rack with 2 rack units 2U of available space Have a standard touch tone telephone available to program the AG17 after installation is complete See Programming below Secure the unit to the rack Ensure all devices that will be connected t...

Page 8: ... See Unit Operation and Programming the AG17 below Apply power to all input devices Unit Operation Default Settings Pulse Trigger Logic Input 60 dB Attenuated Tones All Clear Tone Enabled Timer Reset Disabled Channel 1 Beep High Channel 2 High Low Channel 3 Warble Channel 4 Yelp Fast Channel 5 Whoop Slow Channel 6 Siren Channel 7 Steady Channel 8 Beep Low Alarm Logic Inputs Logic Input Channels ar...

Page 9: ...itch resets it The unit is preset with the Timer Reset disabled so tones continue to sound until the reset switch is pressed To enable the Timer program the unit Timer duration on the AG17 can be programmed for tones operating from 30 seconds to 30 minutes Tip The Timer determines the length of time the alarm sounds before it automatically resets Pressing the Reset switch clears the highest priori...

Page 10: ... same level as the tones generated by the AG17 Output Volume Control Output Volume controls the Audio output of the AG17 The Audio Output level can be adjusted according to the input requirements of the external device e g amplifier being connected Clear Reset Terminals Pulse triggered alarms are reset by the reset feature Level triggered alarms are reset by the removal of the level activation log...

Page 11: ...ng programming you can check parameters to confirm programming accuracy Follow the Setting Tables below and use the touch tone telephone keys to program the AG17 See Programming Displaying All Parameters Stored in Non Volatile RAM below When programming is complete disconnect the telephone from the AG17 Setting Input Channel Alarm Tones Press the key then the Channel Number 1 8 then the Alarm Tone...

Page 12: ...ed inputs 10dB Tone attenuation 0 2 Level triggered inputs 20dB Tone attenuation 0 3 Level triggered inputs 60dB Tone attenuation 0 4 Level triggered inputs Tone totally muted 0 5 Pulse triggered inputs 10dB Tone attenuation 0 6 Pulse triggered inputs 20dB Tone attenuation 0 7 Pulse triggered inputs 60dB Tone attenuation 0 8 Pulse triggered inputs Tone totally muted 0 9 Default Settings Pulse trig...

Page 13: ...en the 0 four distinct pattern sequences will be observed The LEDs will flash in 0 5 second intervals 1 The first sequence will be the flashing of LEDs 1 4 Count the number of flashes and refer to Section 1 LED Input Triggering Mode and Attenuation for the selected operation 2 The second sequence will step through the eight LEDs Count the number of flashes on each led and refer to section 2 for th...

Page 14: ... X Channel 2 1 10 Flashes X X ON X X X X X Channel 3 1 10 Flashes X X X ON X X X X Channel 4 1 10 Flashes X X X X ON X X X Channel 5 1 10 Flashes X X X X X ON X X Channel 6 1 10 Flashes X X X X X X ON X Channel 7 1 10 Flashes X X X X X X X ON Channel 8 1 10 Flashes SEQUENCE 3 ON ON ON ON X X X X All Clear Tone Enabled X X X X ON ON ON ON All Clear Tone Disabled SEQUENCE 4 ON X X X X X X X Flash Ti...

Page 15: ...RY CONTACT RELAY MINIMUM OPEN COLLECTOR OPEN DRAIN OUTPUT 5V 1 mA MIN ALARM LOGIC OUTPUTS 8 MAXIMUM OPEN DRAIN OUTPUT 300 mA 40VDC MAX AUDIO OUTPUT OUTPUT IMPEDANCE 33 OHMS 1VRMS MAX CONTROL OUTPUT VOLUME CONTROL POT AUDIO SIGNALS ALARM TONES TONE 1 SIREN 400 HZ 1000 HZ 0 3 SECONDS TONE 2 WARBLE 400 HZ 1000 HZ 0 3 SECONDS TONE 3 YELP SLOW 400 HZ 1000 HZ 4 2 SECONDS TONE 4 YELP FAST 400 HZ 1000 HZ ...

Page 16: ...0 VAC 1 A MAX VDC 30 VDC 2 A MAX PROGRAMMING JACK RJ11C MECHANICAL BODY CONSTRUCTION MILD STEEL POWDER COATED BODY DIMENSIONS 419 X 207 X 77 MM 16 5 X 8 2 X 3 1 IN NET WEIGHT 3 2KG 7 LBS CONNECTION AUDIO REMOVABLE CONNECTION PLUG CONNECTION LOGIC REMOVABLE CONNECTION PLUG CONNECTION POWER 120VAC U GROUND POWER CORD MOUNTING STANDARD RACK MOUNTING 2 UNITS ...

Page 17: ...ng adjustments and replacing components following the instructions in the product manual Before opening this telephone disconnect the wiring at the demarcation block High voltages may be present in this product when connected to telephone wiring Service Telephone Number 1 800 363 8010 Guardian Telecom provides a customer service telephone number which is toll free within North America If you need ...

Page 18: ...information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product In addition to the RMA number shipping documents should include name address and telephone number of the owner along with contact information for the person responsible for the repair and or the user who identified the malfunction Where a produc...

Page 19: ...Guardian Telecom Inc Installation and Operation Model AG17 Page 19 Notes Model No Part No Serial No Date of Purchase ...

Page 20: ...elecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 http www guardiantelecom com E mail mailto sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom Inc 2015 ...

Reviews: