Guardian Telecom Inc.
Installation and Operation
Model AG17
Page 13
Setting the Timer for Pulse-Triggered Logic Inputs
Press
the
*
key, then the
Timer Duration Number (1-9)
.
*
Timer Duration 1 - 9
*
1
= 30 seconds
*
2
= 1 minute
*
3
= 2 minutes
*
4
= 5 minutes
*
5
= 10 minutes
*
6
= 15 minutes
*
7
= 20 minutes
*
8
= 30 minutes
*
9
= Timer Disabled - all tones continue to sound
until reset.
Setting the All Clear Tone
Press
the
#
key, then the number
9
, then the
Enable or Disable Number
(1-2)
.
#
9
1 = Enable
#
9
2 = Disable
Interpreting the LED Display Pattern Table
After pressing the * and then the 0, four distinct pattern sequences will be observed. The LEDs will
flash in 0.5 second intervals.
1. The first sequence will be the flashing of LEDs 1 – 4. Count the number of flashes and refer to
Section 1, LED Input Triggering Mode and Attenuation for the selected operation.
2. The second sequence will step through the eight LEDs. Count the number of flashes on each led
and refer to section 2 for the alarm tone that is programmed for that channel.
3. The third sequence is for All Clear Tone and LEDs 1 – 4 will flash if it is disabled and 5 – 8 will
flash if activated as Section 3 indicates.
4. The final sequence involves only LED #1 for Flash Timer Correlation. Count the number of flashes
and refer to Section 4 for the selected timing.