Installation and Use
Components and Specifications
Materials: aluminum.
Hole #1
Hole #4
Hole #6
Hole #5
Hole #3
Hole #2
Prior to use, plan your system:
1. All PFAS equipment must be selected and deemed compatible with Rope Anchor by a Competent Person.
2. Eliminate or minimize all risk of swing fall.
3. Ensure selected installation location is compatible with Rope Anchor, and is free of all damage, including,
but not limited to, rot, rust, cracking, sharp or abrasive edges and surfaces, and hazardous materials.
4. Rope Anchor MUST be used with rope 5/8” - 3/4” in diameter only.
Installation:
Rope Anchor may be connected to a compatible vertical lifeline (VLL) or rope lanyard in two different fashions:
1. Compatible rope may be threaded through holes #1-5 and tied off at hole #5. Hole #6 may then function as
an anchorage connector.
2. Compatible rope may be threaded through holes #1-6 and system may wrap around a compatible anchor
point.
Two or more
snap hooks or
carabiners
connected to
each other.
NO.
Connector
directly to
horizontal
lifeline.
NO.
Incompatible
or irregular
application,
which may
increase risk
of roll-out.
NO.