Components and Specifications
Part #
Bolt Size
Description
00370
00372
00371
D-Bolt Anchor (bolt not included). Galvanized steel.
1/2”
5/8”
3/4”
D-Bolt Anchor (bolt not included). Galvanized steel.
D-Bolt Anchor (bolt not included). Galvanized steel.
00374
5/8”
D-Bolt Anchor (bolt not included). Stainless steel.
Installation and Use
Prior to installation, plan your system:
Type A anchorage connector.
Minimum permitted service temperature: -30° F.
5,000 lb. MBS (minimum breaking strength).
Materials: galvanized steel or stainless steel.
MINIMUM substrate thickness requirements:
• Wood: 6”.
• Metal: ¼”.
• Concrete: 6”, 4,000 psi.
Fastener requirements (per part #):
• 00370: 13 TPI bolt. Torque to 65-75 ft-lbs.
• 00371: 11 TPI bolt. Torque to 145-155 ft-lbs.
• 00372: 10 TPI bolt. Torque to 240-250 ft-lbs.
• 00374: 11 TPI bolt. Torque to 145-155 ft-lbs.
ALWAYS defer to torque ratings specified by fastener manufacturer. If fastener torque requirements are
not specified, refer to above recommended fastener/torque ratings. NEVER over-torque fastener.
For wood and metal installations, pre-drill pilot hole 1/16” diameter larger than applicable bolt size.