Issue 08/2013
Page 88
M
A
PL
A - M
odu
la
r e
ne
rg
y s
up
pl
y s
ys
te
m f
or l
oa
d li
ft
in
g m
ag
ne
ts
Installation and commissioning
Generator installation for iMAPLA 25 and 30
Assembly
Ö
Fig. 32, Assembly of flange mount hydraulic drive (iMAPLA 25 and 30),
>
Place the flange
[1]
onto the generator and secure with four screws
[2a]
.
Place a toothed washer
[2b]
underneath the screws and secure with
Loctite.
>
Mount the first half of the coupling
[3]
on the shaft at the generator and
prevent it from twisting on the shaft using with a key.
>
Mount the washer
[4]
onto the hydraulic motor
[6]
.
>
Place the second half of the coupling
[3]
to the hydraulic motor.
>
Place the hydraulic motor
[6]
with washer
[4]
and second half of the
coupling to the generator. Where necessary, turn the coupling slightly to
ensure the gearing locks.
>
Place toothed washers
[5b]
to eight screws
[5a]
and secure disk
[4]
to the
flange
[1]
.
>
Place the collar
[7]
onto the coupling unit and tighten firmly with two
screws.
8x
4x
2a
2b
5a
5b
M12x40 DIN
912
DIN
128 A-12
M8x30 DIN
912
DIN
128 A-8
7
6
5a
5b
4
3
2a
2b
1
2a
M12 x 40 DIN 912
2b
A-12 DIN 128
5a
M8 x 30 DIN 912
5b
A-8 DIN 128
Fig. 32 Assembly of flange mount hydraulic drive (iMAPLA 25 and 30)