Page 107
Issue 08/2013
Operation
Daily inspection of the insulation monitor
The MMI is not supplied with voltage by the generator
(External power supply)
y
Switch on the voltage supply for the MMI.
The green LED 1 then lights up.
y
Start the drive unit.
>
The
i
MAPLA system is ready for use as soon as the drive unit runs at the
required speed and drives the generator.
>
Check the insulation monitor.
Ö
Daily inspection of the insulation monitor, page 107
6.5
Daily inspection of the insulation monitor
Check the correct function of the insulation monitor every day before
starting work.
>
Press the check button for the insulation monitor on the left side of the
MMI.
If the insulation monitor is working correctly, LED 4+5+6 flashes at the same time
when the check button is pressed.
>
Release the check button.
Clear the LED.
Important.
If the LEDs do not flash together, this means the insulation monitor is faulty.
>
Switch off the
i
MAPLA system immediately.
Ö
Insulation monitor faulty, page 128
>
Continue with setting the operating mode.
Warning
Risk of accident
y
If there is not a PE/PA connection between controller and
magnetic housing, the reliable detection of external ISO faults
in the lifting magnet is not assured.
►
For this reason, when deploying an insulation monitor,
the electrical potential connection of the magnet to the
controller must be assured.