GTO FM143 Installation Manua Download Page 5

Copyright © 2021 Nortek Security & Control LLC

5

Dual Gate Installation

Turn power switch OFF on the bottom of the control box. Disconnect gate openers by removing hairpin clip 
and clevis pin from the gate bracket end of the openers. Disconnecting the openers will allow the gates to 
swing freely during installation of the gate lock.

NOTE:

 In a DUAL GATE INSTALLATION the gate opener on the same side of the driveway as the control box 

is known as the PRIMARY GATE OPENER and that gate is referred to as the PRIMARY GATE. Conversely the 
gate opener on the other gate is referred to as the SECONDARY GATE OPENER and the gate is referred to as 
the SECONDARY GATE.

IMPORTANT:

 To use the gate lock on a dual gate system, the gate sequencing must be set so the PRIMARY 

GATE opens first and closes last, and the gate lock has to be mounted on the PRIMARY GATE and the 
lock receiver is mounted on the SECONDARY GATE. Some Linear and Mighty Mule gate operators are 
preprogrammed with this functionality. The secondary gate requires a positive stop. If your gates are not 
sequenced in a manner that works like this, you'll have to change the sequencing on your gate opener. Follow 
the instructions in your gate opener installation manual for programming dual gate sequencing.

Step 1: With the gate in the closed position, determine the best location for the lock and lock receiver. The 

lock and receiver must be level and aligned with the opener. Also, the lock should have a solid 
surface or cross member to provide stability (see illustration below).

Step 2: Clamp receiver and lock together (with receiver pin hole and lock slot aligned) to the gates, mark 

their positions to drill holes. The receiver must be mounted on the SECONDARY GATE with 
carriage bolts, not U-bolts, to allow lock to seat properly.

Step 3: Recheck the lock’s position and alignment. Hold latch open with key and operate gate. Drill the 

holes on gate supports through the slots in the lock bracket. U-bolts and saddles can be used to 
mount the lock on chain link gate supports. Secure the lock to the PRIMARY GATE. Install clevis 
pin and locking cap by placing clevis pin through slots in lock receiver and hammering the clevis 
pin into the locking cap, secure the lock bracket and check the alignment again.

Lock and receiver must be level and aligned with opener.

Hold latch open with key to operate gate.
Receiver pin hole and lock slot must line up.

PRIMARY GATE

SECONDARY GATE

500

500

500

Summary of Contents for FM143

Page 1: ...various mounting applications no mounting hardware is provided with the Automatic Gate Lock All necessary mounting hardware can be obtained from your local hardware store all other hardware is provided This manual shows two examples of the most common installations and should provide insight into most other applications If you have any questions during installation please call 800 543 1236 for tec...

Page 2: ...ons Parts Included A Lock with 20 of low voltage wire B Lock Receiver C Clevis Pin D Locking Cap E Lock Board Battery Lead Wires F White Wire motor lead to lock board G Lock Control Board Lock PCB Not required for most systems H 2 Double Spade Tongue terminals I 6 Nylon Cable Tie J Wire Connector K Lock Keys for manual release L Lock Decal AUTOMATIC GATE LOCK D E F G H I J K L C 3 Diameter B 2 2 A...

Page 3: ... 2 Clamp receiver and lock together with receiver pin hole and lock slot aligned against the gate post mark their positions to drill receiver holes see Illustration B and C page 4 The receiver must be mounted with carriage bolts not U bolts to allow lock to seat properly Fasten the receiver to the gate post Step 3 Hold latch open with key to operate gate and check closed limit and lock alignment D...

Page 4: ...s before drilling holes in fence post Illustration B Iron or Aluminum Tube Fence and Gate Installation Illustration C Chain Link Fence and Gate Installation Illustration D Locking Cap Assembly Clevis Pin Receiver Locking Cap GTO Automatic Gate Lock Carriage bolts washers and nuts not provided size of fasteners depends on the gate Remember to check the alignment and mark positions before drilling h...

Page 5: ...hange the sequencing on your gate opener Follow the instructions in your gate opener installation manual for programming dual gate sequencing Step 1 With the gate in the closed position determine the best location for the lock and lock receiver The lock and receiver must be level and aligned with the opener Also the lock should have a solid surface or cross member to provide stability see illustra...

Page 6: ...ck is keyed for manual release Should the electronic release be disabled for any reason simply use the key to manually open the lock Keys are unique for security purposes and can not be replaced by Nortek Security Control A locksmith will be required if all copies of the keys are lost ...

Page 7: ...s operators WHT GRN LOCK PWR AUX RLY POWER INPUT CONTROL OUTPUTS 2ND OPERATOR 18 VOLT TRANSF OR SOLAR PANEL 1 2 Wiring the lock to MM272 HD272 MM262 MM362 MM462 Operators and Linear Pro 2000XLS series VAR5 K1 PF1 K2 BATT B K3 K4 VAR4 VAR3 VAR2 VAR1 MIN MAX OFF REMOVE JUMPER FOR PUSH TO OPEN OPTION 120 SEC STALL FORCE OPEN JOG CLOSE PWR SET LIMIT 1st OPR 2nd OPR STATUS AUTO CLOSE SFTY EXIT CYCLE ED...

Page 8: ...R1 VAR4 VAR5 VAR6 CYCLE EXIT SAFETY COM CHGR CHGR Wiring the lock to MM360 Operators NOTE Dip switch 4 must be set to LOCK OFF CHARGING POWER RCVR GRN BLK RED EXIT SAFETY EDGE CYCLE COMMON LINK AUX OUT SOLAR INPUT 18VAC H L 1 ON 2 3 4 15 CHARGING POWER RF PULL PUSH MODE1 MODE2 LOCK BEACON OFF 120 CLOSE TIME SET LIMIT LEARN REMOTE AUX OUT SOLAR PANEL 18VAC RCVR GRN BLK RED EXIT SAFETY EDGE CYCLE CO...

Page 9: ...ntrol board lead wire Attach the BLACK lock board battery lead wire to the double spade tongue connector with the BLACK control board Lead Wire Step 6 Connect the WHITE wire from the lock board directly to the PRIMARY OPERATOR terminal block along with the power cable wire from the opener arm Connect the WHITE wire to the RED terminal for a Pull to Open installation or connect WHITE wire to the BL...

Page 10: ...ll does not operate properly contact Technical Support Technical Support 800 543 1236 IMPORTANT For the optimum service and safety find the ideal stall force sensing setting for your gate opener Depending on the weight of your gate the ideal setting will be just enough to move your gate without self obstruction stopping or reversing due to its own weight yet sensitive enough to reverse and stop wh...

Page 11: ... due to failure to follow the manufacturer s instructions or arising from improper installation storage or maintenance EXCEPT FOR THE EXPRESS WARRANTIES EXPRESSLY CONTAINED IN THIS LIMITED WARRANTY NORTEK CONTROL MAKES NO OTHER PRODUCT REPRESENTATIONS OR WARRANTIES OF ANY KIND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING IMPLIED WARRANTIES OF TITLE NON INFRINGEMENT MERCHANTABILITY AND FITNESS...

Page 12: ...ity Control 5919 Sea Otter Place Carlsbad CA 92010 USA Phone 800 421 1587 www mightymule com www nortekcontrol com www linear solutions com 2021 Nortek Security Control LLC All rights reserved Mighty Mule GTO Access Systems and Linear are registered trademarks of Nortek Security Control LLC ...

Reviews: