background image

vi

  GTO 2002XLS Instruction Manual © 01.12.12

IMPORTANT SAFETY INSTRUCTIONS

  7.  To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page 

iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO 

Service Department.

  8.  Disconnect the operator 

ONLY

 when the power is 

TURNED OFF 

and the gate is 

NOT 

moving.

  9.  Make arrangements with local fire and law enforcement for emergency access.
  10.  Distribute and discuss copies of the 

IMPORTANT SAFETY INSTRUCTIONS 

section of this manual with all 

persons authorized to use your gate. 

 11.

 IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate 

and gate operator are aware of the dangers associated with automated gates. In the event you sell the 

property with the gate operator or sell the gate operator, provide a copy of these safety instructions to 

the new owner. 

 

  Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO web site 

(www.gtoaccess.com), by contacting Gates That Open, LLC., at 3121 Hartsfield Road, Tallahassee, Florida 
32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.

Required Safety Precautions for Gates

Install Warning Signs

Warning signs

 

alert people of automatic gate operation and are 

required 

when installing the GTO Gate Operator.  The 

Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed 
for pedestrian traffic. We recommend using the 

GTO Bulldog Pedestrian Gate Lock

 

[FM145] for controlled access.

Entrapment Protection

GTO’s inherent obstruction settings, even when properly adjusted, 

may not be sensitive enough to prevent bodily 

injury in some circumstances. 

For this reason, safety devices such as safety edge sensors (or photoelectric sensors), 

which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against 

entrapment.

Warning Sign 

Warning Sign 

Contact Sensor 

(

recommended, not included

Contact Sensor 

(

recommended, not included

 Pedestrian Gate 

Bulldog Pedestrian  

Gate Lock 

(recommended, not included

)

  

Vehicular Gate 

Photo Beam

Photo Beam

Vehicular Gate 

Contact Sensor 

(

recommended, not included

Contact Sensor 

(

recommended, not included

Summary of Contents for 2002XLS

Page 1: ...at Open LLC from any and all liability If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this produc...

Page 2: ...Restricted Access Vehicular Gate Operator Class IV A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restrict...

Page 3: ...ly 8 Check Clearance 9 Install Gate Bracket 10 Attach Operator Arm 10 Installation of Closed Position Stops 11 Mount the Battery Box Control Box 13 Connect the Battery Box Control Box 14 Connect Opera...

Page 4: ...justable stall force This safety feature makes the gate stop and reverse direction within two seconds when it comes in contact with an obstruction The MIN setting means the gate will exert the minimum...

Page 5: ...ed installed and maintained automated gate operator systems Keep in mind that the gate operator is just one component of the total gate operating system Each component must work in unison to provide t...

Page 6: ...per for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or replace all worn or d...

Page 7: ...ea Driveway 10 10 10 10 10 10 NEVER INSTALL any control device within gray area III After Installation 1 Attach the warning signs included to each side of the gate to alert the public of auto matic ga...

Page 8: ...by contacting Gates That Open LLC at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Saf...

Page 9: ...ate system B A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage C A wireless...

Page 10: ...rians must use separate entrance WARNING MOVING GATE Can Cause Injury or Death 1 800 543 GATE 4283 www gtoaccess com 2002XLS PROFESSIONAL RESIDENTIAL 9901178 TO MANUALLY OPEN AND CLOSE THE GATE 1 Turn...

Page 11: ...pull tube fully retracted is 33 3 4 mounting point to mounting point arm stroke 15 max Minimum gate length is 5 ft Adjustable auto close 3 to 120 seconds and stall force potentiometers Power terminal...

Page 12: ...er source you will need to use at least 5 watts solar charging power to charge the battery FM122 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Oper...

Page 13: ...tal Cross Member Vertical Cross Member Your Property Your Property Pull To Open arm retracts to open Push To Open arm extends to open 3 Prepare the Gate The gate must be plumb level and swing freely o...

Page 14: ...ENER Gate Bracket 2 Post Pivot Bracket 2 Post Bracket 4 Closed Position Stop Plate 2 Hairpin Clip 4 5 16 x 1 3 4 Bolt 2 3 8 x 2 Bolt 2 3 8 x 2 3 4 Bolt 4 3 8 x 8 Bolt 8 8 Nylon Cable Tie 28 3 8 Washer...

Page 15: ...e post bracket Page 9 Depending upon the diameter of the post you may need longer bolts than those provided Bolts should be at least 1 longer than the diameter of the post Page 9 Metal plate for woode...

Page 16: ...positions Horizontal Cross Member Gate Swings Evenly and Freely Hung Firmly and Plumb Post Bracket Assembly Control Box Battery Box Gate Bracket Master Gate Opener Fence Post Set in Concrete Run 1000...

Page 17: ...nd washers out of the wood The post pivot bracket may not be necessary on posts larger than 6 in diameter see page 6 Fence posts smaller than 6 in diameter or 6 square should be made of metal instead...

Page 18: ...et will have to be adjusted later 3 8 x 2 Bolt 3 8 Nut Post Pivot Bracket Post Bracket Post Bracket 3 8 Lock Washer 3 8 Washer Step 2 Attach post bracket assembly to the rear mount of the opener with...

Page 19: ...t binding at the post pivot bracket If you don t have the required clearance or if the gate opener is binding on the post pivot bracket remove the 5 16 x 1 3 4 bolt and readjust the post pivot bracket...

Page 20: ...late Created for Decorative Gate required but not supplied Remove excess bolt length with hacksaw or bolt cutters FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW Round Metal Post Round Wood Post Square Meta...

Page 21: ...nd gate opener on the opposite side of the driveway from the control box will be referred to as the SECOND gate and gate opener Illustration A Closed Position Stop Plate mounted horizontally on metal...

Page 22: ...e the closed position stop plate toward the ground stop until they touch Illustration C Once you have moved the stop plate to the correct position tighten its hardware completely NOTE For a push to op...

Page 23: ...eration is subject to the following conditions 1 This device may not cause harmful interference 2 This device must accept an interference that may cause undesired operation Transmitter distance may va...

Page 24: ...Step 5 Tuck the excess battery leads into the battery box and reattach the CONTROL BOX to the BATTERY BOX Step 6 Remove the Control Box Cover Remove the four 4 control box cover screws and remove the...

Page 25: ...trol board to the battery at distances up to 1000 DO NOT use telephone wire or solid wire NEVER SPLICE WIRES Splicing permits corrosion and seriously degrades the wire s ability to carry an adequate c...

Page 26: ...ee F L R4722 STALL FORCE OPEN JOG CLOSE PWR SET LIMIT 1st OPR 2nd OPR STATUS AUTO CLOSE SFTY EXIT CYCLE EDGE SENSOR COMMON LOCK LOCK WHT GRN RED BLK WHT GRN SECOND OPR FIRST OPR RED BLK 14 VAC OR SOLA...

Page 27: ...and CLOSE buttons to fine tune the gate position if neccessary Step 4 With the gates in in the desired closed positions PRESS and HOLD the SET LIMIT button until the alarm and RED Light come on Then...

Page 28: ...Set Auto Close Time The Auto Close determines how long the gate will remain open before it automatically closes The factory setting is OFF Use a small flat blade screwdriver you can adjust the setting...

Page 29: ...5 feet FCC WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment In accordance with FCC...

Page 30: ...to open the gate and it fully retracts to close the gate C 2 You will install the operator while the gate is in the CLOSED POSITION arm fully retracted A 3 You must use the Push to Open Post Pivot Bra...

Page 31: ...on when the gate reaches the desired open position limit Use the JOG OPEN and CLOSE buttons to fine tune the gate position if neccessary C Press and HOLD the SECOND Opener OPEN button on the control b...

Page 32: ...inal Insert the other solar panel wire into the remaining 14VAC OR SOLAR terminal The wires can be connected to the 14VAC OR SOLAR terminals regardless of color polarity Step 4 Tighten set screws agai...

Page 33: ...VAR6 K1 PF1 K2 BATT BATT K3 K4 VAR4 VAR3 VAR2 VAR1 MIN MAX OFF JP1 REMOVE JUMPER FOR PUSH TO OPEN OPTION 120 SEC GTO Inc Ta l l a h a s s e e F L R4722 STALL FORCE OPEN JOG CLOSE PWR SET LIMIT 1st OPR...

Page 34: ...the operation as follows OPEN STOP CLOSE STOP OPEN 4 EDGE SENSOR Typically for use with contact edge sensor Activation of this input while gate is moving will cause it to reverse direction for 2 secon...

Page 35: ...between the operator mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traffic hazards terrain etc another option is to re hang the g...

Page 36: ...the transmitter button will shut off the alarm c Rapid beeping Unit has encountered two 2 obstructions without reaching either limit Power cycle to reset the alarm Transmitter will not operate the gat...

Page 37: ...________________ 13 8 to 14 8 Vdc Measure voltage at battery terminals with battery disconnected Gate and Opener Maintenance 1 Keep gates properly maintained Grease hinges Make sure gates remain level...

Page 38: ...uired to send in your original equipment for repair Please refer to Manufactures Limited Warranty for complete details Securely pack the component s authorized for return to the factory Include a copy...

Page 39: ...RB741 RB742 RB743 Purchase an additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the...

Page 40: ...vehicle exits the property 100 ft range between transmitter and receiver Easy installation LOCKING SECURITY ACCESSORIES Automatic Gate Lock FM144 The 1 Accessory For Swing Gate Operators Designed for...

Page 41: ...rd 14 volt 1430 mA AC transformer included with the 2002XLS to maintain battery charge Gate Grounding Kit R4196 The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment...

Page 42: ...32 GTO 2002XLS Instruction Manual 01 12 12 Notes...

Page 43: ...GTO 2002XLS Instruction Manual 01 12 12 33 Notes...

Page 44: ...3121 Hartsfield Road Tallahassee Florida USA 32303 850 575 0176 Fax 850 575 8912 Web site www gtoaccess com 24 7 Troubleshooting Wizard http support gtoinc com PROFESSIONAL RESIDENTIAL ACCESS SYSTEMS...