TD-L354P User Manual
7
Installation
Clamps installation
The fixture can be placed on the stage or mounted on the truss facing any direction. The fast-lock clamp gives a quick and
easy lock on the truss.
Warning
Use one clamp when mounting the fixture. Fasten the screw properly and connect a safety cable to fixture.
Device installation
1.
Make sure there is no damage on the clamps or safety cables before installation.
2.
The clamp is mounted on the holder of the fixture. Horizontally insert the clamp into the mounting holes of the holder.
Fasten the clamp tightly.
Placed on the floor Hanging on the truss
Power/ Control connection
Power connection
Connection method:
L (Live) Brown wire
E (Earth) Yellow / Green bi-color wire
N (Neutral) Blue wire
The voltage and frequency of the power source must be in compliance with the ones marked on the fixture. Please
apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the
power source. When the voltage is 220V, maximum 12 sets of fixtures could be allowed in each series connection.
Another series connection should be set up for extra fixtures.
Notes
It is essential that each fixture is correctly grounded and the electrical installation conforms to all relevant Standards / Codes
of Practice for Safe Electrical Work.