background image

 

GTD-L2016P User Manual 

Menu structure 

L2016P – Menu Structure 

Revision: A 

Valid from firmware version: 1.0 

 

Level 1  Level 2 

Level 3 

Level 4 

Info 

Addr

 

A

XXX 

 

A001

 

 

 

Setting the DMX address 

Play

 

RUN

   

MSTR

/

ALON

 

 

Running build-in program as the master or the slave 

AUDI

 

MSTR

/

ALON

 

 

Receiving sound signal as the master or the slave 

AUTO

 

Clos

/

Hold

/

Auto

/

Audi

   

Setting the status when no DMX signal received 

CH

 

CH2

 

 

 

Standard channel mode 

CH1

 

 

 

Basic channel mode 

MIC

 

M

-

XX

   

M

-

72

 

 

 

Adjusting the sensitivity of Microphone 

DISP

 

VALU

 

D

–XX

   

D

-

00

 (

D

XXX

)  

 

Display the channel value 

D

 

ON

 

ON

/

OFF

 

 

Turn on or off    the Backlight time function 

EDDY

 

ON

/

OFF

 

 

Inverted Display 

SET

 

RDMX

 

ON

/

OFF

 

 

Allow the console to change the Address   

DEFA

 

ON

/

OFF

 

 

Factory reset 

FANS

 

AUTO

/

HIGH

/

LOW

 

 

Setting the Fans’ status 

Save

   

OFF

/

1

-

99M

 

15M

 

 

Close the LED light when no signal 

Ver

 

V1.0

~

V9.9

 

 

Software version 

STAT

 

R

-xx

 

xxx 

 

Manual control 

Edit

 

SEPR

 

AUTO

 

IP01

~

IP10

 

 

Selecting the program that want to edit 

STEP

 

S

01

 ~

S

48

 

 

Setting the steppes of program 

SC

XX

 

C

01

~

C

–XX

 

XXX

(

0

~

255

)  

Editing program by manual 

TIME

 

T

 XXX

(

001

~

999

)  

Running time 

CEDT

 

ON

/

OFF

 

Receiving build-in program from console or not 

REC.

 

RE

.XX

 

 

Recording senses automatically 

RUN

 

ON

/

OFF

 

 

Program test 

SDMD

 

MOD0

~

MOD5

 

MOD1

 

 

Dimmer mode select 

Notes 

Settings highlighted in light grey are default values. 

Summary of Contents for GTD-L2016P

Page 1: ...LED Effect Light GTD L2016P User s Manual Guangzhou GTD Lighting Technology Co Ltd Tel 86 20 61808296 Fax 86 20 61812282 http www gtd lighting com ...

Page 2: ...panies and are hereby acknowledged All non GTD brands and product names are trademarks or registered trademarks of their respective companies GTD and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained with...

Page 3: ... Accessories 5 Product introduction 6 Installation 6 Device installation 6 Power Control connection 7 Power connection 7 Control connection 7 Testing 7 Control panel 8 Menu structure 9 DMX protocol 10 Technical specification 14 Cleaning and maintenance 15 Troubleshooting 16 System wiring diagram 17 Spare parts list 17 Appendix 1 17 ...

Page 4: ...G Fire hazard It s essential that the fixture is properly grounded Only qualified personnel should perform electrical connections WARNING Wear protective eyewear Never look directly into the light source Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Before ap...

Page 5: ...e changing any parts or accessories Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures clamps cables auxiliary equipment etc Check that the cover clamps and locks are undamaged Certified safety cables must always be used when installing the fixture The fixture is only intended for installation operation and maintenance by qualified p...

Page 6: ...foam from the top put away the accessories and then take out the fixture wrapped in the plastic bag Packing after use 1 Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power Cool down the fixture for at least 15 minutes before packing 2 Flight case Wrap the fixture in plastic bags Hold it by the handles and then carefully place it inside the flight case along...

Page 7: ...DMX output 4 Power output 5 DMX indicator 6 MENU UP DOWN ENTER buttons 7 Power input 8 Cast aluminm cover 9 LED lens 10 Bracket 11 Manual adjusting screw Installation Device installation This fixture can be installed on stage or mounted in any directions On the wall On the ground ...

Page 8: ...o all relevant Standards Codes of Practice for Safe Electrical Work Control connection The fixture has 5 pin XLR connectors for DMX data input and output 3 pin optional as shown below Connection between the console and fixture and between fixtures must be made with 2 core screened DMX signal cable Maximum connecting distance of signal cable is 150 meters Additional DMX512 signal amplifier is recom...

Page 9: ...s ENTER to choose a function and enter into corresponding sub menu Each menu represents a specific function of the fixture Press ENTER to select the specific function and save the changes or enter into the submenu then press UP or DOWN to change the value of the selected function increase or decrease Press MENU to return to the previous menu or exit LED indicators Power on RED power LED indicator ...

Page 10: ...lue D ON ON OFF Turn on or off the Backlight time function EDDY ON OFF Inverted Display SET RDMX ON OFF Allow the console to change the Address DEFA ON OFF Factory reset FANS AUTO HIGH LOW Setting the Fans status Save OFF 1 99M 15M Close the LED light when no signal Ver V1 0 V9 9 Software version STAT R xx xxx Manual control Edit SEPR AUTO IP01 IP10 Selecting the program that want to edit STEP S 0...

Page 11: ... 100 0 No light Full light 0 0 6 Blue 1 0 255 0 0 100 0 No light Full light 0 0 7 white 1 0 255 0 0 100 0 No light Full light 0 0 8 Red 2 0 255 0 0 100 0 No light Full light 0 0 9 Green 2 0 255 0 0 100 0 No light Full light 0 0 10 Blue 2 0 255 0 0 100 0 No light Full light 0 0 11 white 2 0 255 0 0 100 0 No light Full light 0 0 12 Red 3 0 255 0 0 100 0 No light Full light 0 0 13 Green 3 0 255 0 0 1...

Page 12: ... Green 10 0 255 0 0 100 0 No light Full light 0 0 42 Blue 10 0 255 0 0 100 0 No light Full light 0 0 43 white 10 0 255 0 0 100 0 No light Full light 0 0 44 Red 11 0 255 0 0 100 0 No light Full light 0 0 45 Green 11 0 255 0 0 100 0 No light Full light 0 0 46 Blue 11 0 255 0 0 100 0 No light Full light 0 0 47 white 11 0 255 0 0 100 0 No light Full light 0 0 48 Red 12 0 255 0 0 100 0 No light Full li...

Page 13: ...2 255 91 0 100 0 Rainbow flow from slow to fast 69 8 Dimmer mode 0 5 0 0 2 0 M0 600Hz Gama1 5 Smoth 0 0 6 11 2 4 4 3 M1 600Hz Gama1 5 Snap 12 17 4 7 6 7 M2 1200Hz Gama1 5 Smoth 18 23 7 1 9 0 M3 1200Hz Gama1 5 Snap 24 29 9 4 11 4 M4 600Hz Gama2 0 Smoth 30 35 11 8 13 7 M5 600Hz Gama2 0 Snap 36 255 14 1 100 0 Reserved 70 9 Flash effects 0 15 0 0 5 9 No function 16 20 6 3 7 8 Flash effect 1 21 25 8 2 ...

Page 14: ...ash effect 27 151 155 59 2 60 8 Flash effect 28 156 160 61 2 62 7 Flash effect 29 161 165 63 1 64 7 Flash effect 30 166 170 65 1 66 7 Flash effect 31 171 175 67 1 68 6 Flash effect 32 176 180 69 0 70 6 Flash effect 33 181 185 71 0 72 5 Flash effect 34 186 190 72 9 74 5 Flash effect 35 191 195 74 9 76 5 Flash effect 36 196 200 76 9 78 4 Flash effect 37 201 255 78 8 100 0 Reserved 71 10 Flash speed ...

Page 15: ... Weight 10 kg 22 lbs IP rating IP65 Material Aluminum steel Minimum distance to combustible materials 1 64ft 0 5m Minimum distance to illuminated surfaces 3 28ft 1m Dynamic effects Strobe 1 20Hz synchronized pulse effects Dimmer 0 100 16 bit electronic linear dimming 600Hz 1200Hz smooth or snap dimmer mode optional Thermal Operating range 14 F to 113 F 10 C to 45 C Startup range 5 F to 113 F 15 C ...

Page 16: ...ic color filters or housing of the fixture If the lens is cracked or otherwise damaged replace it immediately If the LED lamp becomes damaged or deformed in any way it must be replaced If the light from the LED lamp appears dim this normally indicates that it is reaching the end of its life span and should be changed at once Aged LED lamps run to the extremity of their life might explode If fixtur...

Page 17: ... of the fixture Choose the channel mode in Channel setting Channel Mode of the fixture as required by the user Malfunctioning of DMX cannon input output connectors No input output voltage to the main control board of the fixture Troubleshooting the DMX XLR signal plate of the fixture replace the main control board of the fixture LED lamp off There is no signal output to the main control board PWM ...

Page 18: ...203K01 204K01 LCR0542B 4CPU program control board 2 5809211002B 1 L2016P 301K01 302K01 303K01 304K01 LCR0542B 4CPU Display board 5809210073D 1 L1516P 101K10 L2016P 101K12 SDI0516D 1 Appendix 1 GTD L2016P L N GE 12V 12V ESS170 12PN POWER L N GE 12V 12V POWER JC1 JF1 JF2 JE1 JE2 5 J2 J1 SDI0516C JC JIN1 LJB0523C LJB0523C ESS170 12PN JC LCR0542B LCR0542B J2 JE2 JE1 J1 JE1 J1 J2 JE2 Water proof socket...

Page 19: ...GTD L2016P User Manual 18 Notes P N 1502011061B Time September 25th 2017 ...

Reviews: