12.
13.
www.gtpower.co.nz
www.gtpower.co.nz
GT3500SE
Alternating Current (AC)
Connection
WARNING:
Before starting the engine,
do not connect any electric devices.
Turn the ESC switch to “OFF” (1).
NOTE: Be sure all electric devices
including the lines and plug connections
are in good condition before connecting
to the generator.
Be sure the total load is within generator
rated output.
When starting the engine, with the ESC “ON”
and there is no load on the generator: In
ambient temperature (below 0
o
C ), the engine
will run at the rated (3600r/min) for 5 mins to
warm up the engine.In ambient temperature
(below 5
o
C ), the engine will run at the rated r/
min (3600r/min) for 3 minutes to warm up the
engine.
The ESC unit operates normally after the
above time period, while the ESC is “ON”.
Stopping The Engine
a. Release the load.
1. Turn off and disconnect any electrical
devices.
2. Turn the ESC to “OFF” (1).
3. Turn the 3 in 1 switch to “OFF” (2) .
a. Ignition circuit is switched off.
b. Fuel valve is switched off.
Be sure the receptacle load current is
within receptacle rated current.
Summary of Contents for GT3500SE
Page 1: ...GT3500SE...
Page 23: ...23 www gtpower co nz GT3500SE Electrical Diagram 230V 50Hz...
Page 26: ...26 www gtpower co nz GT3500SE...
Page 27: ...27 www gtpower co nz GT3500SE...