background image

 

   

VIII  WEEE Information 

2012/19/EU 

(WEEE 

directive): 

Products  marked  with  this  symbol 
cannot  be  disposed  of  as  unsorted 
municipal  waste  in  the  European 
Union.  For  proper  recycling,  return 
this  product  to  your  local  supplier 

upon the purchase of equivalent new equipment, 
or dispose of it at designated collection points.   

IX  Limited Warranty   

GST

  warrants  that  the  product  will  be  free  from 

defects  in  design,  materials  and  workmanship 
during  the  warranty  period.  This  warranty  shall 
not  apply  to  any  product  that  is  found  to  have 
been improperly installed or used in any way not 
in  accordance  with  the  instructions supplied  with 
the  product.  Anybody,  including  the  agents, 
distributors or employees, is not in the position to 
amend  the  contents  of  this  warranty.  Please 
contact  your  local  distributor  for  products  not 
covered by this warranty. 

 

 

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for I-9602LW-LPG

Page 1: ...www acornfiresecurity com www acornfiresecurity com...

Page 2: ...IPTION 1 II CONNECTION AND WIRING 1 III MOUNTING 2 IV APPLICATION 4 V MAINTENANCE 5 VI CAUTIONS 6 VII SPECIFICATION 7 VIII WEEE INFORMATION 8 IX LIMITED WARRANTY 8 www acornfiresecurity com www acornf...

Page 3: ...n polarized Z1 Z2 Loop non polarized V V To pipe solenoid valve When the detector alarms 3s to 7s later there is a 12V pulse between V and V K1 K2 Normally open passive contact it is closed when alarm...

Page 4: ...ables according to terminal instructions and installation and operation manual Finally install the detector on the base Mounting is shown in Fig 2 Sensitive Position 5 8 7 6 1 4 3 2 Fig 2 When the det...

Page 5: ...detector at following locations Where directly affected by smoke or vapor from the stove Where near strong airflow such as air inlets fans doors etc Where near bathroom or places with a lot of vapor...

Page 6: ...lication 1 After wiring and checking apply power supply green LED should flash After warm up for 3 to 6 minutes the detector works normally and lights steadily 2 When the detector is in alarm state Al...

Page 7: ...rns with three sounds of the buzzer V Maintenance 1 The detector should be tested half a year at least Use a gas cigarette lighter to test the detector the distance should be longer than 10cm Press th...

Page 8: ...near smoke exhauster Keep environment around the detector clean 3 We recommend use JJ or FCR series solenoid coming with the detector If other models are to be used please consult us 4 Don t cut off...

Page 9: ...efied petroleum gas Alarm Threshold 10 LEL propane Ingress Protection Rating IP30 Ambient Temperature 10 50 Relative Humidity 95 non condensing Material and Color of the Enclosure ABS ivory Weight 180...

Page 10: ...rrants that the product will be free from defects in design materials and workmanship during the warranty period This warranty shall not apply to any product that is found to have been improperly inst...

Page 11: ...www acornfiresecurity com www acornfiresecurity com...