background image

 

GST-MNA2C/GST-MNA2F Network Annunciator                

                                              

Installation and Operation Manual

                 

                                                

 

 

Page 22  

6  Operating Instructions 

6.1 Panel Control Keys 

6.1.1 

MANUAL ALARM 

(User password) 

When the 

MANUAL ALARM

 key is pressed, the following actions will be produced: 

  Displaying a manual alarm message in LCD. 

  Lighting the 

FIRE ALARM

 LED and

 

MANUAL ALARM

 LED. 

  Extinguishing the 

SILENCE ALARM 

LED if it illuminates. 

  Turning on the buzzer. 

  Writing manual alarm record in 

FIRE ALARM INFORMATION

 and history file. 

6.1.2 

ACKNOWLEDGE

 

(User password) 

Pressing 

ACKNOWLEDGE

 key will acknowledge a new fire, fault, or supervisory event. 

Pressing 

ACKNOWLEDGE

 key will result in the following actions:  

  Lighting the 

ACKNOWLEDGE

 LED. 

  Marking an acknowledgement to the event displayed. 

  Writing acknowledgement record in history file. 

  Information of higher level will be displayed if there is more information. Pressing 

ACKNOWLEDGE

 

repeatedly can toggle between different types of information 

and pressing up and down key can view them. 

6.1.3 

SILENCE

 ALARM 

(User password) 

SILENCE ALARM

 

key

 

is used to silence the notification appliances. When this key is 

pressed, the following actions will be produced:  

  Silencing the notification appliances.  

  Lighting

 the 

SILENCE ALARM

 

LED.  

  Writing silence alarm records in history file. 

  If new alarm occurs, the silenced notification appliances will

 

resound, and 

SILENCE

 

ALARM

 

LED turns off. 

6.1.4 

SILENCE BUZZER 

(User password) 

When the

 

SILENCE BUZZER

 

key is pressed, the following actions will be produced: 

  Silencing the buzzer of the Annunciator. 

  Lighting the 

SILENCE BUZZER 

 LED. 

  Writing silence buzzer records in history file. 

  If new event occurs, the silenced buzzer will

 

resound, and 

SILENCE

 

BUZZER 

 

Summary of Contents for GST-MNA2C

Page 1: ......

Page 2: ...4 User Interface 11 5 Operations 13 5 1 Setup on the annunciator 13 5 1 1 Basic Setting 13 5 1 2 Advanced Setting 15 5 2 Programming the annunciator Through GstNDef Defining Tool 16 5 2 1 Download th...

Page 3: ...ork Annunciator Installation and Operation Manual Page II Appendix B Electrical Specifications 25 B 1 Electrical Specifications 25 B 1 1 Input Power 25 B 1 2 CAN Network 25 B 1 3 Fiber Optical Network...

Page 4: ...s unit until this manual is read and understood This equipment must be installed in accordance with these instructions and the appropriate national regional and local regulations specific to the count...

Page 5: ...to make certain that all accessories have been included Cabinet key Manual 1 2 Standard Features The annunciator provides the following Receive message from FACP through network Send command Reset Sil...

Page 6: ...MNA2C CAN interface Class A Maximum distance between two neighbor nodes is 2500m with 18AWG or 3000m with 16AWG GST MNA2F Fiber interface LC monomode fiber Maximum distance between two neighbor nodes...

Page 7: ...en connected including LCD drive board main board indicator board and main front panel before the annunciator leaves the factory Therefore you can mainly check the connection among parts including the...

Page 8: ...GST MNA2C GST MNA2F Network Annunciator Installation and Operation Manual Page 5 Fig 3 1...

Page 9: ...iator LCD doesn t light and all LEDs are illuminated for 5s As All LED go out LCD displays Data Loading and GST logo Initiation of the system takes about 85s 90s Self test of LEDs on the front panel S...

Page 10: ...Fig 3 3 3 4 2 Network Connection Class A The GST MNA2C has a CAN type interface Fig 3 4 is for CAN network connection and the GST MNA2 F has a FIB type interface Fig 3 5 is for Fiber connection S1 _O...

Page 11: ...eset Silence Buzzer 1 2 3 4 5 6 7 8 9 0 Power Pre Alarm General Trouble System Trouble FIRE Alarm Ground Trouble Supervisory Disable Delay Mode Maintenance Test Mode Day Mode Fire Alarm Information In...

Page 12: ...rouble It lights when any card is fault or definition of devices linkage equation is incorrect it goes out as the fault is removed General Trouble It lights when there is fault message it goes out as...

Page 13: ...al is the indication of restoration to normal condition For non latching supervisory the signal will be locked in until manually reset Supervisory information screen is displayed when there is supervi...

Page 14: ...item or confirm an operation BACKSPACE key Press this key to delete an input number or letter SPACE key Press this key to input a space character 4 4 User Interface The annunciator has a touch screen...

Page 15: ...Clicking SUPERVISORY tab can view details TROUBLE trouble messages take lower priority than supervisory messages The trouble messages will be displayed if there is no Alarm or supervisory messages Cl...

Page 16: ...c Setting Password clicking Password in Basic Setting menu enters the screen for setting passwords as shown in the figure below Fig 5 2 There are two types of passwords including User Password and Eng...

Page 17: ...lation and Operation Manual Page 14 Fig 5 3 Clicking the message in Indicator Info can enter the screen to define Fascia Button LED Definition as shown in Fig 5 4 Fig 5 4 Clicking Undefined can define...

Page 18: ...below Fig 5 6 Fig 5 6 Panel No input the number of the annunciator here Delay Setting Users can set delay based on the actual situation by clicking Delay Setting in Advanced Setting menu as shown in...

Page 19: ...save the configuration and definition to a USB stick and then insert the USB stick into the USB port on the SD 400 LCD Drive Board of the annunciator Fig 5 9 Clicking Maintain Database in Advanced Set...

Page 20: ...in the same subnet as the programming computer Fig 5 10 Clicking Computer in Fig 5 9 pops up the screen as shown in Fig 5 11 At this time the configurations and definitions can be downloaded to the an...

Page 21: ...option refer to the figure above Fig 5 12 5 3 2 Display Setup Clicking Display Setup in User Setup menu enters the screen for setting font size LCD backlight time and so on Refer to the figure below F...

Page 22: ...ng is a supplementary function The external printer shall be UL ITE listed equipment which connects to annunciator internal USB port The interconnecting USB cable between annunciator and printer shall...

Page 23: ...nual Page 20 Fig 5 16 5 3 5 Day Night Mode Clicking Day Night Mode in User Setup menu Day Night mode can be set Refer to the following figure Fig 5 17 Fig 5 17 In this mode starting and ending time fo...

Page 24: ...Clicking Language Setup in User Setup menu enters the screen for setting the language Refer to the figure below Fig 5 19 Fig 5 19 5 3 7 Project Information Clicking Project Information in User Setup...

Page 25: ...riting acknowledgement record in history file Information of higher level will be displayed if there is more information Pressing ACKNOWLEDGE repeatedly can toggle between different types of informati...

Page 26: ...in history file 6 1 6 RESET User password Pressing the Reset key the following actions will be produced Extinguishing all LEDs except of POWER LED and turning off the buzzer Turning off all notificat...

Page 27: ...twork Annunciator Installation and Operation Manual Page 24 Appendix A Basic System Connection GST MNA2C POWER INPUT 24V 24V CAN_H1 CAN_L1 CAN_H2 CAN_L2 MAIN CARD GST MNA2F POWER INPUT 24V 24V TX RX T...

Page 28: ...00mA Max current 400mA Wire size minimum 16AWG maximum 550 m per line B 1 2 CAN Network Class A Maximum distance between two neighbor nodes is 2500m with 18AWG or 3000m with 16AWG Maximum 250 nodes fo...

Page 29: ...ervice department Return product transportation prepaid to the manufacturer This writing constitutes the only warranty made by this manufacturer with respect to its products The manufacturer does not...

Page 30: ...Gulf Security Technology Co Ltd No 80 Changjiang East Road QETDZ Qinhuangdao Hebei P R China 066004 Tel 86 0 335 8502434 Fax 86 0 335 8502532 service gst fs utc com www gst com cn...

Reviews: