In case Output 

Signal 

wavelength is  

not shown flat  

or looks like  

oscillation 

* Check connection fastened 

between antenna and cable  

(Signal wavelength should be 

flat and stable if technicians 

shake CABLE. If not, it is 

connection problem.) 

 

 

* If connection is not proper, reconnect cable and connector 

and then check the output power again. 

Same as above 

* Input level change or    

module overheating.  

* Check input level from BTS side. 

* Check performance of each module. 

(Diagnosed by A/S team.) 

Same as above 

* Please check VSWR of the 

Cable is normal.  

* Change to normal Cable.  

 

 

4.2.6 Troubleshooting Guide Related to NMS 

Symptom 

Check Points 

Troubleshooting 

Link Fail  

* Communication problem 

* In case of Ethernet, verify IP addressing, DHCP function, and 

that Cookies are deleted. 

* Verify that a crossover Ethernet cable is being used. 

Link Fail  

* CLI Connection, Cable       

status check  

* Make sure 1:1 connection. 

* Follow instructions in the installation guide for this connection 

procedure. 

Link Fail  

* CLI connection Check by 

USB to Serial Cable  

* Please verify Port number of PC communication. 

* Please check Cable connection status. 

 

 

Summary of Contents for GRS-1915D-SPR

Page 1: ...3G Indoor Repeater GRS 1915D SPR User Manual January 2009 Version 0 1...

Page 2: ...11 3 2 System Specifications 12 3 3 Electrical and Environmental Specifications 12 3 4 Functions 13 4 SETUP 15 4 1 Equipment Needed for 3G Indoor Repeater Setup 15 4 1 1 Checkpoints before turning on...

Page 3: ...ildings to transmit Sprint signals at PCS 1900MHz band Characteristics PCS Band 72dB Gain with 15dBm maximum composite output power Bandwidth Entire PCS 1900 frequency A Block to F Block 45MHz Bandwid...

Page 4: ...is replaced by an incorrect type Caution Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment Warning Exposure to Ra...

Page 5: ...Sprint User Manual 3G Indoor Repeater 5 2 System Configuration 2 1 3G Indoor Repeater Service Network Configuration Pic 1 3G Indoor In building Repeater Service Organization...

Page 6: ...Sprint User Manual 3G Indoor Repeater 6 2 2 System Design and Operation 2 2 1 System Design Pic 2 GRS 1915D SPR repeater...

Page 7: ...Sprint User Manual 3G Indoor Repeater 7 Pic 3 Internal Design No Part 1 Module 2 Control Board 3 Ethernet Board...

Page 8: ...Sprint User Manual 3G Indoor Repeater 8 Pic 4 Outside Port Design NO PORT 1 Server Antenna Port 2 Donor Antenna Port 3 DC Power Port 4 CLI Monitor Port 5 Ethernet Port 6 Grounding port...

Page 9: ...ath received from Donor Antenna signal is transferred through Duplexer DPX and Down Conversion DNC module and after choosing one of 5MHz 10MHz or 15MHz in IF path the signal is forwarded to Up Convers...

Page 10: ...Table Pic 6 1900MHz Band Structure PCS 1900 repeater has 5MHz 10MHz 15MHz Paths in IF division so any of these bandwidths can be selected for providing service 5MHz 10MHz 15MHz are only continious ban...

Page 11: ...IONS 3 1 System Capacity Item Specification Remark Downlink 1930MHz 1975MHz 45MHz Freq Uplink 1850MHz 1895MHz 45MHz Donor CDMA Tx Rx DPX Port Server CDMA Tx Rx DPX Capacity OMNI Channel Capacity 5MHz...

Page 12: ...nk Noise Figure 5dB Max gain 12dB Min gain Roll off 1 0MHz 50dBc Test frequency measured from band edge Characteristic Impedance 50 3 3 Electrical and Environmental Specifications Item Specification R...

Page 13: ...A G S A G S A G S O S C IL L A T IO N A L A R M O F F O S C IL L A T IO N A L A R M O F F O S C IL L A T IO N A L A R M O F F O S C IL L A T IO N A L A R M O F F Y N Y N Y N Y N Y N AGC Auto Gain Cont...

Page 14: ...ater Maximum and minimum set up is possible Shutdown in over temperature Automatic recovery after temperature becomes normal Hysteresis 10degree IP address report via E mail When in PPP reconnection E...

Page 15: ...erver ANT 1 EA 1 EA Not Included RF Cable Antenna connection Cable TBD Not Included Testing and Measuring Equipment Spectrum Analyzer 1 EA Not Included 4 1 1 Checkpoints before turning on the Repeater...

Page 16: ...e Repeater and then it will be ready to use 3 For grounding there is a grounding terminal in main power supply which will be plugged into power outlet There is also a separate grounding terminal on th...

Page 17: ...on will be optimized 2 Check points after open a Check external LED 1 RUN Green light ON Off all lights off 2 ALARM Green light in normal status Red light in alarming 3 SHUT DOWN Green light in normal...

Page 18: ...erminal which is provided by Spectrum Analyzer Output power generation status system spurious emission characteristics c Verification of signal quality and strength in service area User should verify...

Page 19: ...F Power Meter 10Watt Max 50ohm b Signal Generator 3GHz c Spectrum Analyzer 3GHz d Multi Meter 4 2 2 Notice a Troubleshooting should be performed by a trained technician b Parts that seem to be not use...

Page 20: ...pen for service Please check quantity of all accessories with specification before you set up Fit cable length in accordance with field condition Set up 1900MHz CDMA Donor antenna to secure Isolation...

Page 21: ...ing normally Reset Adapter upon completing Alarm troubleshooting When in alarming UL over output alarm Please make sure output level is operating normally Please reset Adapter upon completing Alarm tr...

Page 22: ...When output power is no longer problem Cable connector loose It is possible for connectors to get too tight and damage the equipment or throughput Please contact installer or service provider upon ver...

Page 23: ...k performance of each module Diagnosed by A S team Same as above Please check VSWR of the Cable is normal Change to normal Cable 4 2 6 Troubleshooting Guide Related to NMS Symptom Check Points Trouble...

Reviews: