- 29 -
PSPT 1000
—> The "Displaying the output data rate" – "
DATARATE
" menu is acti-
vated.
d
isPl aying
the
outPut
data
r ate
This menu shows the output data rate defined using the COFDM settings and
the current output data rate.
Bx 4A
/B
17,1 / 31,5 MBits
DATARATE
17,1
: Shows the current output data rate in mBits.
31,5:
Maximum possible output data rate in mBits.
—> If the current output data rate reaches 90% of the maximum output
data rate the LED (page 9) of the corresponding channel strip light
up orange. If the current output data rate reaches 99% of the maxi-
mum output data rate the LED (page 9) of the corresponding channel
strip blinks red.
• Press the
button.
—> The "Setting the transport stream / ORGNET-ID" – "
TS/ONID
" menu
is activated.
s
et ting
the
tr ansPort
strea m
/ orgnet-id
If the stations of a transponder are split into the transport streams of the chan-
nel strips "
A
" and "
B
", one of the both transport streams a new identification
(ORGNET-ID) must be allocated to realise the channel search of the set-top
boxes connected without mistakes.
If the ORGNET-ID is changed a new NIT must be generated.
Bx 4A
/B
0x0001,0100
TS/ONID
• Use the
buttons to position the cursor under the digit of the hexadeci-
mal number to be set.
• Press
to set the respective digit of the hexadecimal number.