![GSS PHIS 1000 S Assembly Instruction Manual Download Page 36](http://html.mh-extra.com/html/gss/phis-1000-s/phis-1000-s_assembly-instruction-manual_2275475036.webp)
- 36 -
PHIS 1000 S
Copying the settings to all IP outputs
• Pressing the
button the settings "Quantity of the data packets",
Forward error correction" and "Transmission channel" can be copied to all
IP outputs.
—> The display shows "
copy
" for a short time.
• Press the
button.
—> The "Setting the output data rate" – "
DATARATE
" menu is activated.
s
et ting
the
outPut
data
r ate
In this menu you can set the output data rate of each IP output optionally to
automatic (auto) or to a fixed value.
IP 1
( 7.3)
>
DATARATE
!
10.0 MB
—> The sum of the output data rates of all IP outputs must not exceed 80
Mbps (100-BASE-T interface).
The current needed data rate is shown on the left side in parentheses (e.g.
7.3 MBits). This indication is dropped at setting "auto".
• Use the
buttons to position the cursor under the digit of the data rate
displayed to be set.
• Using the
buttons set the desired data rate.
—>
Indication ">"
: Current needed data rate of this IP output is higher
than the data rate set (overflow).
Indication "!"
: The sum of all output data rates set is higher than
80 MBits.
• Press the
button.
—> The "Allocating services manually" menu is activated.