- 32 -
HDMC 1000 C
• Press the
button.
—> The "Substitute signal in the case of an incorrect input signal" –
"
FAILURE
" menu is activated.
s
ubstitute
signal
in
the
Case
of
an
inCorreCt
inPut
signal
You use this menu to set whether a QAM signal filled with "
Null Packets
", a
QAM signal filled with null packets and self-made tables "
Tables
" or a "
Sin-
gle Carrier
" signal should be provided as an output signal whenever an
incorrect input signal occurs. Self-made tables are transmitted furthermore.
Bx 4A
/B
Single Carrier
FAILURE
•
Use the
buttons to set the output signal required.
• Press the
button.
—> The "Transport stream ID and the ORGNET-ID" – "
TS/ONID
" menu
is activated.
t
r ansPort
strea m
id
and
the
orgnet-id
If the stations of a transponder are split into the transport streams of the chan-
nel strips "
A
" and "
B
", one of the both transport streams a new identification
must be allocated to realise the channel search of the settop boxes connected
without mistakes.
If the ORGNET-ID is changed a new NIT must be generated (page 33).
Bx 4A
/B
0x0001,0100
TS/ONID
off
• Use the
buttons to position the cursor under the digit of the hexadeci-
mal number to be set.
•
Press
to set the respective digit of the hexadecimal number.
• Repeat the procedure by the quantity of the digits to be set.
• Using the
button place the cursor under "
off
" and switch "
on
" the trans-
mitter identification using the
buttons.