- 31 -
HDMC 1000 C
o
utPut
data
r ate
Bx 4A
SR=6900 (6325)
STUFFING
Number 1 Number 2
SR=6900
(= "Number 1"): Active output symbol rate
(
6325
) (= "Number 2"):
The current measured output symbol rate.
If the station filter is activated, this value is lower than the value of the
"Number 1". The value fluctuates, since the data rates of individual stations
are dynamically modified by the broadcasters.
—> "Number 2" is not displayed in the channel strips "
A
" or
"
B
" at the settings "
OUTROUTE 1=>ASI ASI=>MA
" or
"
2=>ASI ASI=>MB
", for the symbol rate of the ASI input signal
cannot be measured. The ASI input signal therefore must be built
in such a way so that the output symbol rate ("Number 1") is not
exceeded.
The symbol rates of the transport streams built by the cassette can be
measured at the setting "
OUTROUTE ASI=>ASI
" and be displayed
in the respective channel strip.
•
Use the
buttons to place the cursor under the number to be changed
("Number 1") and set the symbol rate with the buttons
. The value
set corresponds to the new output symbol rate.
Increasing the value of "Number 1".
—> The "Number 1" can be increased to any value up to 7500.
Reducing the value of "Number 1".
—> With the station filter switched "
on
", the "Number 1" can be de-
creased. To do this, observe the "Number 2" for approx. 30 seconds
and note the highest value. Add roughly 10 % to this value. Do not
decrease the "Number 1" lower than the value of "Number 2".
Is the "Number 1" lower than "Number 2" question marks "
??
" ap-
pear in the display.
Bx 4A
SR=6500 (6650) ??
STUFFING