background image

Assembly Instruction

Default access data:

192.168.0.120

User: admin

Password: geheim

STC 4-16 IPS CI

Summary of Contents for Compact Classic STC 4-16 IPS CI

Page 1: ...Assembly Instruction Default access data 192 168 0 120 User admin Password geheim STC 4 16 IPS CI ...

Page 2: ...g 9 3 Assembly 10 3 1 Installing the device 10 3 2 Device overview 11 3 3 Potential equalisation PE 12 3 4 Connecting the device 12 3 5 CI Slots 13 4 Configuration Updates 14 4 1 Initial configuration 14 4 2 Configuration 17 Overview window 17 Perform changes 18 Number format 18 Configuration menus 19 Input 19 Output 21 CA 28 System menus 30 Logbook 30 Notification 31 Network 33 OpenVPN 34 Securit...

Page 3: ...lites 40 Overview 40 Menu Configuration Input 41 Installing the SDUC 516 42 Potential equalisation PE 42 Connecting the SDUC 516 43 Appendix 44 Panasonic VIERA TV Sets 44 Configuration steps at the head end station 44 Upload the M3U List directly to the TV sets 44 Upload a link to the M3U List to the TV sets 44 Configuration steps at the VIERA TV Sets 44 Enable DVB via IP reception 45 DVB via IP U...

Page 4: ...e head end station should only be installed in a room where the permis sible ambient temperature range 0 C 50 C can be maintained even during fluctuations in climatic conditions Make sure there is a minimum space of 10 cm on either side and 50 cm above and below To avoid too strong interacted heating of the head end stations it is not admissible to mount them one upon the other without using therm...

Page 5: ...uest The licensee is granted a non exclusive right of use for the Open Source Software by the respective right holders used the conditions stipulated by the respective valid license terms apply The license terms of this license only apply to the components which are not listed as Open Source software In relation to the licensor the regulations on liability and warranty in these license terms apply...

Page 6: ...014 30 EU 2014 35 EU The product fulfils the guidelines and standards for CE labelling page 46 Unless otherwise noted all values are specified as typical RF input DVB S S2 ETSI 300 421 Frequency range 950 2150 MHz DVB S modes QPSK DVB S2 modes QPSK 8PSK 16APSK 32APSK Symbol rate DVB S QPSK 1 45 MSymb s Symbol rate DVB S2 QPSK 4 5 45 MSymb s 8PSK 4 5 45 MSymb s 16APSK 4 5 39 MSymb s 32APSK 4 5 32 M...

Page 7: ...ace for configuration Standard 100 BASE T Connections SAT inputs 4 F sockets LAN output for streaming 1 RJ 45 socket LAN input for configuration 1 RJ 45 socket Common Interfaces 6 General Mains voltage 200 240V 50 60 Hz Power consumption without LNC CI 30 W Maximum Power consumption 55 W Admissible ambient temperature 0 50 C Dimensions WxHxD 341 x 282 x 105 mm Weight 7 kg ...

Page 8: ...AT IN 2 SAT IN 3 f1 f2 f3 f4 f1 f2 f3 f4 f1 f2 f3 f4 f1 f2 f3 f4 General The station is equipped with four SAT IF inputs one Gbit LAN data output and one 100Mbit configuration LAN input It is preset to receive the most popular ASTRA transponders Different programming is possible at any time Each of the 16 tuners can be assigned to any SAT input Using adequate CA modules scrambled channels can be d...

Page 9: ... 16 LEDs provide an indication of the SAT IF input signal quality based on their colour Streaming Live Streaming Multicast Streaming requires specially designed and config ured networks Make sure the LAN network is adapted and configured for streaming Therefore note menu Help Multicast Setup or www mygss eu Service Service Informations IPTV network setup ...

Page 10: ...perature range 0 C 50 C can be maintained even during fluctuations in climatic conditions Mount the device on a non combustible base Use mounting material suitable for the wall properties Position the device with a minimum distance on the left and right side of 10 cm below and above 50 cm Attach four mounting screws at the installation site The drilling distances are shown in the drawing below STC...

Page 11: ...AT IF input vertical high 5 SAT IF input horizontal low 6 SAT IF input horizontal high Factory defaults for ASTRA reception can be changed individually 9 IEC connector C14 connector for mains cable 10 Reset IP address and password hold depressed for more than 5 seconds to 192 168 0 120 for 12 and 192 168 10 120 for 11 Host name gss Password geheim 11 LAN socket streaming output 12 LAN socket for c...

Page 12: ... II mode from page 40 on Connect the attached mains cable to the IEC connector C14 9 Connect the mains cable to a mains socket with protective conductor con nection Thereby note the voltage specified on the device This device has no power switch and starts immediately after con necting the operating voltage For a complete disconnection from the mains the mains plug must be pulled out of the mains ...

Page 13: ...CA module is not sufficient to descramble all channels of a transponder alternatively the modules 6 4 can be assigned to the tuners 1 3 additional Module 1 6 for tuner 1 Module 2 5 for Tuner 2 and Module 3 4 for Tuner 3 Insert the CA modules for slots 1 3 with the thicker top side towards housing front for slots 4 6 with the thicker top side towards rear panel heat sink 1 6 2 5 3 4 Final mount aga...

Page 14: ... cable directly to the configuration input 12 The PC and the head end station must be within the same network same IP address range Cookies must be accepted and JavaScript must be active Use current browser versions Example for IP address setting with Windows 7 operating system For the initial setup open the properties for TCP IPv4 of the PC Control Panel Network and Sharing Center LAN connection ...

Page 15: ... 16 IPS CI Internet Protocol Version 4 TCP IPv4 Properties Activate point Use the following IP address Enter e g 192 168 0 2 for the IP address Enter for the Subnet mask 255 255 255 0 Confirm the setting with OK ...

Page 16: ...nd that you replace the default password to a pass word of your choice in order to prevent unauthorized access to the head end station menu System Security For further logins observe the menus System Network and System OpenVPN The Overview window is displayed First an empty table is displayed as with all menus While the data is read from the device is displayed Changes in the menus are only transm...

Page 17: ...n Overview 52 Via the selection Configuration you have access to the Configuration set ting menus Input page 19 Output page 21 CA page 28 53 Herein the installed firmware version is displayed 54 ThislocationtextcanbemodifiedarbitraryinmenuSystem User page39 If you remote control head end stations at different locations herein you can enter the location and a local contact person 55 Select menu lan...

Page 18: ... NOT assigned the name of the first station of each transponder is displayed The maximum displayed C N value is 15 0dB at DVB S resp 20 0dB at DVB S2 This means the actual value is 15 20dB 61 Via button Download a configuration protocol can be stored as text file respectively opened using a text editor From this protocol file e g a list of the programmed stations can be prepared using e g a text e...

Page 19: ...lumn fLNB enter the LNB Oscillator frequencies for the 4 inputs de pendent on the LNB used In dCSS Unicable II operating this column is omitted You need Quattro LNBs with 9 75 10 6 GHz oscillator frequency For multiple satellite reception observe the dCSS Unicable II mode from page 40 on 101 In column Name enter a personal input name If dCSS Unicable II is activated you can assign the four levels ...

Page 20: ... enter the desired input frequency for each tuner 107 In column SR kS s enter the related input symbol rate for each tuner 108 In column foffset the current frequency offset is displayed The frequency offset should not exceed 1 5 MHz IF necessary correct the LNB oscillator frequency if all transpond ers of one input are affected resp the input frequency if only one transponder is affected accordin...

Page 21: ...in select the protocol UDP or RTP for all output streams For Panasonic TVs RTP must be set 151 Herein you can switch off the transmission of the EPG data Electronic Programme Guide in order to reduce data rate for more services 1 5Mbit s for EPG per service are quite possible EIT Event Information Table ...

Page 22: ...s SPTS streams The input line e g L01 line 1 tuner 1 and service ID type are displayed in the bracket 157 Indication of the Multicast IP Addresses Multicast IP addresses are assigned to the streams 153 IGMP capable switches recognize the addresses automatically and if configured ac cordingly route the streams only on request to end devices This greatly reduces network traffic IP addresses in the r...

Page 23: ... only for those columns for which you have entered changes If you set a check mark at Output change the corresponding outputs are switched on or off depending on selection You can delete the contents of the columns Service Prog No and SAP group when selecting reset for each column In the Start IP field you can enter the output IP address for row 1 This address is then increased by 1 in each additi...

Page 24: ...oup column Announcement delay indicates the interval at which the data is sent Change the value only if the clients have problems with receiv ing the SAP data 163 If this switch is set to ON the services of other stations which are oper ated in parallel are added to the M3U xml lists 164 and the documenta tion list 165 The query is made via the configuration interfaces The IP addresses of the conf...

Page 25: ...r the configuration or streaming interface This file contains the path to the service list M3U list that you can load into the clients In this way future changes to the service list are automatically adopted by the client The clients require a permanent connection to the head station Select the Configuration file for the interface with the corresponding IP range You will find hints about the TVs s...

Page 26: ... the Channel List Version has in creased If changes are made the version is changed automati cally If you want to integrate the head end station into an existing TV network you can adjust the value to the TV sets in the Channel ListVersion input field BEWATEC IPTV Geräte Here you can download the service list channels_bewatec xml for Be watec IPTVs Alternatively note the path Server URL to the ser...

Page 27: ...st you must execute Apply to create the list It also includes services which are switched off Please also note 73 166 Before leaving the menu changes must be transferred to the head end station Therefore click on button After that is displayed for a short time in the upper right corner ...

Page 28: ...the CA slots If one CA Module is not enough to completely descramble a transponder here in addition you can assign the CA modules 6 4 to lines 1 3 1 Line 1 Line 6 Line 2 Line 5 1 1 2 2 3 3 4 4 5 5 6 6 Line 3 Line 4 6 2 5 3 4 CI 1 6 lines 1 6 1 1 6 2 2 3 3 4 4 5 5 1 Line 1 Line 1 Line 2 Line 5 Line 3 Line 4 6 2 5 3 4 CI 1 6 line 1 CI 2 5 lines 2 5 1 1 6 2 2 5 3 3 4 4 1 Line 1 Line 2 Line 1 Line 2 L...

Page 29: ...eset 203 Via button Open CA Menu you get access to the individual menus of the CAMs content is dependent on the CAM Via pull down menu CA Slot select the corresponding CAM Use the 10 key keyboard to control the menus by mouse click End the CAM settings by Close CA Menu button 204 Herein you can select whether only one line is displayed or all lines are displayed 205 Indication of TS ON ID For ente...

Page 30: ...t be transferred to the head end station Therefore click on button After that is displayed for a short time in the upper right corner System menus Logbook 300 301 302 In the logbook different alerts or events are displayed This helps at a possible troubleshooting 300 Herein you can select whether only one line is displayed or all lines are displayed 301 Via this button you can clear the logbook 30...

Page 31: ... 314 316 313 317 310 311 315 318 319 321 310 Enter the duration in seconds that an input signal or data overflow error must occur for an entry to be made in the logbook 311 Enter here the duration in seconds which must be a signal OK again for an entry to be made in the logbook 312 Herein enter the e mail address to transmit the e mail 313 Herein enter the password for the outgoing mail server of ...

Page 32: ...ly In the e mail the contact details which are stored in menu System User are displayed to identify the head end station 319 Enter here how long new e mails will not be sent In order to prevent you e g in case of changing reception condi tions from being flooded with e mails the function is blocked for this time after sending an e mail The lock can be removed by delet ing the logbook 321 Before le...

Page 33: ...n the network you must enter different names here Write down the IP addresses and the Host name Further access to the device is only possible via the IP address of the configuration interface or the host name If you have forgotten your IP addresses you can reset the network settings and the password by the reset button 0page 11 For remote access it is important to setup a gateway with Internet acc...

Page 34: ... opened e g at the router Open menu System OpenVPN Copy the Personal Link http into the address line of your browser and store it as favourite As there is no Internet connection at the system start for the initial configuration you need to reboot the device after configuration System Firmware Restart If there is no Internet connection at the system start the OpenVPN service is deactivated temporar...

Page 35: ...cess to the station For authorisation enter the old password and after that the new pass word twice Before leaving the menu changes must be transferred to the head end station Therefore click on button After that is displayed for a short time in the upper right corner If you have forgotten your password you can reset the network set tings and the password by the reset button 0 page 11 ...

Page 36: ...342 System settings 332 Herein select the time zone setting dependent on the location of the head end station The head end station receives the Coordinated Universal Time UTC from the satellite Enter the corresponding UTC offset Herein the standard or wintertime must be set In order e g to adjust the Central European Time CET the offset must be set to 1 hour 333 Herein you can switch off or on the...

Page 37: ...nu Therefor the firmware must be previously stored on your PC The current firmware version can be found at www mygss eu Unzip the zip file tar update file added notes A firmware update may take a long time to complete Aborting the firmware update or interrupting the power supply dur ing the update might in worst case result in a defect of the device During the update this warning is displayed Afte...

Page 38: ...ig but ton Load a configuration stored in the manager 340 In the Saved configurations field select a saved configuration and load it with the Load config button Delete a configuration stored in the manager 341 In the Saved configurations field select a saved configuration and de lete it with the Delete config button Reset to factory defaults 342 Reset the head end station to factory defaults via b...

Page 39: ...you want to ping and click the Ping button User In section User you can adjust the location based data that is displayed in the header of the menus accordingly If you remotely manage multiple head end stations you know at any time at which station you just work In the Notes field you can enter any text that will be displayed in the overview as a reference Before leaving the menu changes must be tr...

Page 40: ...iene Potential equalisation rail STC 4 16 IPS CI LNB INPUTS 12V DC LOW HIGH T V H V H LOW HIGH T V H V H LNB OUTPUTS SDUC 516 2 x 16 USER BANDS OUT 1 16 UB GSS Grundig Systems GmbH 90471 Nuernberg Germany OUT 2 16 UB LNB INPUTS 12V DC LOW HIGH T V H V H LOW HIGH T V H V H LNB OUTPUTS SDUC 516 2 x 16 USER BANDS OUT 1 16 UB GSS Grundig Systems GmbH 90471 Nuernberg Germany OUT 2 16 UB LNB INPUTS 12V ...

Page 41: ...II switch in the input settings must be set to ON As a result the preprogrammed frequencies of the SDUCs are set at the inputs of the head station For dCSS Unicable II operation you need Quattro LNBs with 9 75 10 6 GHz oscillator frequency 101 102 103 101 Personal input name 102 LNB supply on off 103 dCSS Unicable II Mode ...

Page 42: ...wall properties If necessary attach four mounting holes at the installation site The drilling distances are shown in the drawing below Fasten the unit LNB INPUTS 12V DC LOW HIGH T V H V H LOW HIGH T V H V H LNB OUTPUTS SDUC 516 2 x 16 USER BANDS OUT 1 16 UB GSS Grundig Systems GmbH 90471 Nuernberg Germany OUT 2 16 UB 95mm 86mm Potential equalisation PE Make a potential equalisation PE according to...

Page 43: ...UB GSS Grundig Systems GmbH 90471 Nuernberg Germany OUT 2 16 UB D E F G H I Connect the SAT IF inputs D G to the corresponding outputs of a quat tro LNB Connect the RF output H to an input of the head end station Screw the DC adapter onto the DC input I Connect the power supply unit to the DC adapter Connect the power supply unit to a mains socket ...

Page 44: ...oad it into a TV set With this option the upload must be done again after any changes in the service list Upload a link to the M3U List to the TV sets Download the link for the M3U list into a configuration file for the TV set 164 page 21 and store it into the root directory main directory of a USB stick in order to load it into a TV set This file contains a link to the service list at the head en...

Page 45: ...n you will find a hint that the M3U list was found on the stick head end station Select Search Channels and press OK to access DVB via IP Update the M3U Liste or Link The following steps must be done if DVB via IP was already acti vated as reception source Display the menu with button MENU Select Setup Tuning Menu Auto Setup and press OK to access Select Start Auto Setup and press OK to access Sel...

Page 46: ...er Straße 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 633 240 0 Fax 49 0 911 633 240 98 www gss de en info gss de Service Phone 49 0 911 633 240 90 service gss de Alterations reserved Technical data E O E by GSS Grundig Systems GmbH V43 010 2019 ...

Reviews: