4.5  Closing the housing cover

 

•  Put the housing cover onto the housing and press it on so that the metal fi ns 

 

 

press against the housing from the inside in closed state. 

 • 

Use 

screw 

B

 to fasten the housing cover (Fig. 1).

5 Specifi cations 

The distribution amplifi ers  fulfi l the directives EN 50083-1, EN 50083-2/class A, 
EN 50083-3/quality class 2, EN 60065 and the guidelines and standards for CE label-
ling.

Unless otherwise stated, these specifi cations are typical values which in practice may be 
higher or lower inside the tolerance range usual for the branch.

Alterations reserved. Technical data E. & O.E.  

© by GSS GmbH 

10072006

AR 5218

AR 5298

forward

return

forward

return

Frequency range

MHz

85 … 862

5 … 65

85 … 862

5 … 65

Gain
Attenuation
Line equalization
Assigned value attenuation

dB
dB
dB
dB

21

0 … -20

0 … 18

19

0 … -20

0 / 10

30

0 … -20

0 … 18

24

0 … -20

0 / 10

Noise fi gure

dB

6

6

Return loss
  (40 MHz, -1.5 MHz/oktave /min. Cat. C)

dB

> 14

17

> 14

17

Impedance

Ω

75

Output level

 

(IMA = 60 dB)

  IMA 2 acc.

 

EN 50083-3

  IMA 3 acc. EN 50083-3
  IMA 3 acc. 

 

EN 50083-5

  CSO Cenelec, 42 Channel 862 MHz
  CTB Cenelec, 42 Channel 862 MHz
  Maximum operating level (EMC)

dBµV
dBµV
dBµV
dBµV
dBµV
dBµV

100
107
113

97

100
105

102
107
113

105
109
115
101
100
110

104
107
113

Power supply
  Supply voltage (50 … 60 Hz)
 Power consumption

V

AC

W

230

5

230

6

Ambient conditions acc. EN 60065
  Operating temperature range
  Degree of protection

 

Protection class

°C

-25 … +55

II, totally insulated

IP 20

Housing
 Weight
  Dimensions (W x H x D)
 Screening attenuation
    acc. EN 0083-2, class A
  HF connections (75 

Ω

)

kg

mm

dB

approx. 0.65

150 x 80 x 50

85 (up to 300 MHz)

F connectors

Summary of Contents for AR 5218

Page 1: ... D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 Email info gss tv Internet http www gss tv Assembly Instructions Assembly Instructions English AR 5218 AR 5298 Distribution Amplifiers A A CLASS CLASS KLASSE KLASSE Grundig SAT SystEms ...

Page 2: ...pter if the amplifier is disconnected from the mains Dispose of the product after use as electronic waste in compliance with the ap plicable disposal regulations 2 Technical description The interactive multimedia capability distribution amplifiers built into a die cast housing are for supplying small building units and CATV house networks Beside the adjustable amplifier they contain the diplex fil...

Page 3: ...G in vertical off 0 dB or horizontal direction on 10 dB Use control D Fig 2 to set the line equalization factory setting full to right 0 dB 4 4 Configuring the return channel Position the jumpers F Fig 2 according to Fig 3 factory setting active HF output return channel input HF input return channel output 158 mm HF output return channel input HF input return channel output 158 mm 20 dB 0 dB 0 dB ...

Page 4: ... 5 65 85 862 5 65 Gain Attenuation Line equalization Assigned value attenuation dB dB dB dB 21 0 20 0 18 19 0 20 0 10 30 0 20 0 18 24 0 20 0 10 Noise figure dB 6 6 Return loss 40 MHz 1 5 MHz oktave min Cat C dB 14 17 14 17 Impedance Ω 75 Output level IMA 60 dB IMA 2 acc EN 50083 3 IMA 3 acc EN 50083 3 IMA 3 acc EN 50083 5 CSO Cenelec 42 Channel 862 MHz CTB Cenelec 42 Channel 862 MHz Maximum operat...

Reviews: