background image

- 2 -

- 2 -

1  Important information on safety and assembly

 •  Mount  the  amplifi er …

 

  -  on a non-fl ammable surface (wall),

 

  -  in a dust-free, dry environment,

 

  -  protected from moisture and water (rain or splashing water),

 

  -  at a place protected from direct sunlight,

 

  -  away from the immediate vicinity of heat sources,

 

  -  taking the maximum permissible operating temperature into account. 

 

• Do not perform installation and service work during thunderstorms.

 

• Only install the unit when disconnected from the 230 V mains power supply.

 

• Check the coaxial cables for short circuits before starting. Eliminate any.

 

• No liability is accepted for any damage caused by a faulty connections and / 

or inexpert handling.

 

• Observe all applicable standards, guidelines and directives (VDE0100, 

VDE0185, VDE0855, VDE0860, DIN18015, EN61319-1, EN50083).

 

• Earth the system via the equipotential bonding connector belonging to the building.

 

• Only open the cover on the mains adapter if the amplifi er is disconnected from 

the mains.

 • Dispose of the product after use as electronic waste in compliance with the ap-

plicable disposal regulations.

2 Technical description

The interactive multimedia capability distribution amplifi ers built into a die-cast housing are 
for supplying small building units and CATV house-networks. Beside the adjustable amplifi er 
they contain the diplex fi lter and the return channel amplifi er. The levels of the input signal 
and of the return channel signal can be adjusted from 0 … -20 dB and the level of the line 
equalization from 0 … 18 dB. The power supply is integrated in the amplifi er housing.

3 Assembly

 Mount the distribution amplifi er in such a way …

 – 

that the convection cooler is not obstructed by the vertical cooling fi ns on the

 

  back of the housing.

 

– that the permissible ambient temperature is maintained (measured in the air-

stream below the housing).

.
 • 

Screw the distribution amplifi er onto the wall according to the dimensions in Fig. 1

  (screws: 

Ø 

 4.8 mm).

 

•  Fasten the earthing line (Cu 

 4 mm

2

) to the earthing connection 

A

 securely.

 

•  Connect HF input and HF output.

Summary of Contents for AR 5218

Page 1: ... D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 Email info gss tv Internet http www gss tv Assembly Instructions Assembly Instructions English AR 5218 AR 5298 Distribution Amplifiers A A CLASS CLASS KLASSE KLASSE Grundig SAT SystEms ...

Page 2: ...pter if the amplifier is disconnected from the mains Dispose of the product after use as electronic waste in compliance with the ap plicable disposal regulations 2 Technical description The interactive multimedia capability distribution amplifiers built into a die cast housing are for supplying small building units and CATV house networks Beside the adjustable amplifier they contain the diplex fil...

Page 3: ...G in vertical off 0 dB or horizontal direction on 10 dB Use control D Fig 2 to set the line equalization factory setting full to right 0 dB 4 4 Configuring the return channel Position the jumpers F Fig 2 according to Fig 3 factory setting active HF output return channel input HF input return channel output 158 mm HF output return channel input HF input return channel output 158 mm 20 dB 0 dB 0 dB ...

Page 4: ... 5 65 85 862 5 65 Gain Attenuation Line equalization Assigned value attenuation dB dB dB dB 21 0 20 0 18 19 0 20 0 10 30 0 20 0 18 24 0 20 0 10 Noise figure dB 6 6 Return loss 40 MHz 1 5 MHz oktave min Cat C dB 14 17 14 17 Impedance Ω 75 Output level IMA 60 dB IMA 2 acc EN 50083 3 IMA 3 acc EN 50083 3 IMA 3 acc EN 50083 5 CSO Cenelec 42 Channel 862 MHz CTB Cenelec 42 Channel 862 MHz Maximum operat...