background image

UP TO 96% EFFICIENT

1.  The quiet, brushless DC blower prepurges the 

submerged combustion chamber for 8 seconds 
and turns off.  

2.  The hot surface igniter is energized and glows red 

hot.

3.  The blower turns on, precisely mixing air and gas 

for combustion.  The mixture is forced through the 
metal fibre burner and is ignited by the hot surface 
igniter.  A blue flame is evenly distributed across 
the entire burner, resulting in clean combustion 
with low nitrous oxide emissions.

4.  The combustion chamber wall transfers high 

temperature heat from the flame to the water.

5.  The blower pushes hot combustion gases through 

the spiral coil, which scrubs theremaining heat 
from the hot gases.

6.  As combustion gas exits the bottom of the spiral 

coil, it is barely warm to the touch.  Up to 96% of 
the heat from the flame is transferred to the water.

7.  Combustion gases are vented through ULC S636 

plastic pipe. 

8.  Condensation formed by cooled combustion air 

is captured by a condensate trap and drained 
through a drain line.

Polaris® High-Efficiency Residential Gas Water Heater 

The perfect choice for combi systems

THE QUIET WAY TO EFFICIENTLY HEAT WATER

An ultra quiet radial blower is combined with a submerged burner for 
whisper quiet operation.  Indicator lights illuminate when the power is 
on and when the igniter and burner are operating.

1

4

7

8

3

2

6

5

Summary of Contents for Polaris PR100-34-2NV

Page 1: ...C PIPE Direct vents up to 120 using ULC S636 PVC or CPVC pipe either Thru the Wall or Thru the Roof Optional concentric vent kit available for use Thru the Roof or Wall PLUG AND PLAY TECHNOLOGY No special adjustments are required at initial start up Connect air inlet exhaust outlet water electricity and gas set the temperature and the system functions properly SELF DIAGNOSTIC CONTROL SYSTEM Three ...

Page 2: ...wer pushes hot combustion gases through the spiral coil which scrubs theremaining heat from the hot gases 6 As combustion gas exits the bottom of the spiral coil it is barely warm to the touch Up to 96 of the heat from the flame is transferred to the water 7 Combustion gases are vented through ULC S636 plastic pipe 8 Condensation formed by cooled combustion air is captured by a condensate trap and...

Page 3: ...air handler Air from the home is warmed as it is blown across the coil Warmed air is returned to the home through air ducts With up to 199 000 BTUs Polaris can heat most homes large or small RADIANT HYDRONIC HEAT Polaris works great for homeowners who prefer radiant hydronic heat With radiant floor hydronic systems potable hot water is circulated through tubes under the floor The floor absorbs hea...

Page 4: ...low NOx less than 40 ng j in the blue flame mode and shall be manufactured of refractory steel resistant to thermal and mechanical shock The gas valve shall be a Honeywell CV1 r1 series gas valve with a matching 45 900 series venturi manifold using a 1 1 air gas ratio The combustion system shall be factory adjusted and require no field adjustment on startup The tank shall be constructed of 444 sta...