How to turn ON / OFF the Alarm
Once you have paired and positioned the sensors and key fobs the alarm is ready to be used.
Arm Using Text Message
To set the alarm to ON you will need to send the text message
#
ALARM
=
ON
#
This will activate the alarm
#
ALARM
=
OFF
#
This will deactivate the alarm
Arm Using the Key Fob
The key fob works best when used with the siren provided as this provides an audible alert whenever you
arm or disarm the alarm.
Press Button A on the Key Fob
This ARMS the alarm.
The siren will beep TWICE
Press Button B on the Key Fob
This DISARMS the alarm
The siren will beep ONCE
Once the Alarm has been alarmed, it will stay alarmed even after an alarm activation, To turn off the
alarm and stop further alarm messages you will have to disarm the alarm by text or key fob
How to Use The Siren Output
The unit has been programmed to trigger the siren for 60 seconds in the event of an alarm activation. Once
the text message has been received you can STOP the siren sounding by pressing B on the key fob.
The length of time the siren sounds for can be altered from 10 to 90 seconds by sending the text command
#
SIREN
=
0
#
Turns siren OFF
#
SIREN
=
1
#
Sets siren to sound for 10 seconds upon activation.
#
SIREN
=
6
#
Sets siren to sound for 60 seconds upon activation (default setting)
#
SIREN
=
9
#
Sets siren to sound for 90 seconds upon activation
Page 6
Activating the Alarm
Once the alarm is armed via text or keyfob, the alarm is then ready and sensing all paired beams.
When a sensor is broken this will trigger the siren for the pre determined length of time and also send a
text message to two pre programmed phone numbers, it will also call if you have set the call on feature
(see page 4)
The text message will relate to which sensor has been broken - you can pair upto 20 sensors and name
them individually to individually name see page 5 . The default texts are IR01, IR02 etc
Once the alarm has been activated , it will automatically re-arm once the beam has been cleared.
Disabling Sensor 1 Only
If you want to remove sensor 1 from operation you send the text command
#
BEAM1
=
ON
#
This will re-enable sensor 1
#
BEAM1
=
OFF
#
This will disable sensor 1
The purpose of this function is to deactivate one sensor whilst retaining the rest of the alarm system, this
could be for a constantly used door during day time hours.