P a ge 4

How to Programme the Mobile Number

After inserting the simcard into the GSM module, turn the unit on and wait until you see
the 

GREEN 

LED come on. This indicates that the module has a signal and the unit is

ready to be used.

Please Note -  To avoid confusion we have colour coded the 

hash

 (

#

) and the 

equals

 (

=

)

symbols. Furthermore, where it indicates a phone number this should be
your number or the numbers you wish the unit to contact.

To programme your phone numbers into the unit you will need to send the text message
as follows:

Example: (

hash

) (PH) (

equals

) (phone number) (

hash

)

#

PH1

=

07123456789

#

  Then send this to the unit simcard number.

#

PH2

=

07753651298

#

  Then send this to the unit simcard number.

The unit will reply number stored

When the unit is triggered it will send an alarm message to thiese numbers

How to programme the SMS Text Message

You can now change the alarm default message from “IR??” To one of your choice.

To change the message send the text command as follows

#

IR01

=

YOUR MESSAGE

 

Default message is IR01

#

IR02

=

YOUR MESSAGE

#

 

Default message is IR02

The detector will reply with the text message - “MESSAGE STORED”

By changing position 01 to 20, you can name all 20 individually paired sensors.

PLEASE NOTE

Your can only use a maximum of 30 characters including spaces for your customised
message.

How to Setup Call Alerts

The auto dialler can be programmed to send you a telephone call after each text alarm
has been sent.
You will receive approximately three ring tones. The unit will then hang up automatically.
This is to prevent call charges being incurred.

To set call alerts to ON please send the text message

#

CALL

=

ON

#

The unit will reply back “call on”

To disarm call alerts please send the text message.

#

CALL

=

OFF

#

You will then revert back to the default text message only alert

Summary of Contents for Alarm Pro 20

Page 1: ...Page 1 2G GSM ALARM PRO 20 ZONES www gsm activate co uk MODEL ALARM PRO 20 ...

Page 2: ...4G 2600 Mhz Power Supply Voltage 9 24 volts DC 2 Amp Min Current Used in Standby Mode 50mA Max IP65 Rated Enclosure for Outside Installation Micro 2G or 3G Simcard No Land Line Required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 40 C Programmed by Text Message Text to Text Signal Strength Wireless Range Beam 50m Key Fob 50m PIR 80m Ba...

Page 3: ... The alarm will perform a test on the signal strength You will receive a text confirming the signal strength between 0 up to 30 We strongly recommend that you place the unit where it can receive a signal of at lease 10 less than this will make the unit unreliable Battery Backup In the event of a power failure the internal rechargable battery will be capable of running the unit for 24 hours It will...

Page 4: ...se numbers How to programme the SMS Text Message You can now change the alarm default message from IR To one of your choice To change the message send the text command as follows IR01 YOUR MESSAGE Default message is IR01 IR02 YOUR MESSAGE Default message is IR02 The detector will reply with the text message MESSAGE STORED By changing position 01 to 20 you can name all 20 individually paired sensor...

Page 5: ...ored to a location it cannot be stored to another location without it being unpaired using a reset Pairing the Key Fobs Press the GREEN key option It will show 3 positions and have an X or symbol this shows whether a keyfob is paired to it Choose a location from 1 3 You will then get a prompt to PRESS KEY FOB A Press the A ONLY on your key fob This will be followed by a beep to signal it has been ...

Page 6: ... for can be altered from 10 to 90 seconds by sending the text command SIREN 0 Turns siren OFF SIREN 1 Sets siren to sound for 10 seconds upon activation SIREN 6 Sets siren to sound for 60 seconds upon activation default setting SIREN 9 Sets siren to sound for 90 seconds upon activation Page 6 Activating the Alarm Once the alarm is armed via text or keyfob the alarm is then ready and sensing all pa...

Page 7: ... and we will do our best to respond to your querry within 24 hours Monday Friday Quick Reference Factory Reset To reset the unit back to factory settings you will need to send the text message RESET PLEASE NOTE By doing this you will reset ALL of your parameters ONLY send this seset command when necessary The GREEN ready LED will flash eight times 20 07 21 GD Page 7 ...

Reviews: