![GSi PNEG-2309 Installation And User Manual Download Page 51](http://html1.mh-extra.com/html/gsi/pneg-2309/pneg-2309_installation-and-user-manual_2275064051.webp)
1. The gate adjustment is an iterative process. Changing one setting will affect the another.
NOTE:
The sealing areas of the gate must be clean before starting the adjustments.
2.
Over Center:
a. The linkage should go “over center” and against a hard stop to hold the drop gate (70) closed
without the assistance of the air cylinder.
b. The over center travel is about 1/8" to 1/4".
c. The gap between the angle irons is 1/4" and the fast evacuation of the product is about 3-5
seconds.
Figure 7-2
Checking the over center
27
Tub
67
Crank
62
Turnbuckle
68
Pinch seal
65
Hinge shaft
69
Rocker
66
Drop gate shaft
70
Gate
PNEG-2309
Horizontal Fertilizer Mixer
51