4. Installation
34
PNEG-2116
Bucket Elevator
Hood Installation
After belt splicing is complete, hoist the hood into position on the elevator head and install the fasteners.
Drive Installation
Refer to the order information and the certified drawings furnished with the elevator for drive installation.
The amount of detail will depend upon whether or not InterSystems furnished all or part of the elevator
drive. Abide by the manufacturer’s instructions packaged with the reducer, motor, couplings, bushings,
etc. Fit and alignment must be held to the limits specified to achieve the expected service life. In any event,
the engineer or contractor overseeing elevator installation is responsible for proper installation and
operation of the elevator drive.
IMPORTANT: Reverse rotation of drive can cause damage to internal elevator and/or drive components.
Be certain to verify correct motor rotation on start-up. If motor rotates in the wrong direction,
change motor wiring to achieve proper rotation.
Figure 4R Typical Shaft Mount Drive Assembly
Ref #
Description
Ref #
Description
A
Belt Guard Cover
F
Motor
B
Belts
G
Belt Guard Mounting Bracket
C
Bushing
H
Shaft Mount Gear Reducer
D
Sheave
I
Gear Reducer Torque Arm
E
Belt Guard Body
J
Torque Arm Gusset