10
PNEG-010
Vane Axial Fan
3. Installation Instructions
Vane Axial Fan Pad
Placement of the Fan Pad: Transitions/Fans/Heaters Only
If a fan or fan and heater is to be installed, refer to
to determine the concrete pad size.
1. The top of this pad should be level with the top of the bin’s foundation.
2. Recommended pad thickness is 4" minimum.
3. Front of pad should be perpendicular to bin wall.
4. Pad for heater not required, but if it is to added, pour the pad to cover both locations.
For fans and transitions used in aeration duct system applications, refer the transition and aeration
installation instructions.
IMPORTANT:
Fan pad and fan must be level and smooth for proper operation. Vibration problems can
result from improper fan leveling.
Figure 3A
TR-4734
A = 20" for fans without heaters
A = 44'' for fans with heaters
TR-6918 and TR-6919
A = 32" for fans without heaters
A = 56" for fans with heaters
TR-7048
A = 45" for fans without heaters
A = 69" for fans with heaters
Summary of Contents for PNEG-010
Page 1: ...PNEG 010 Vane Axial Fan Installation and Operation Model Owner s Manual PNEG 010 Date 02 11 09...
Page 9: ...2 Decals PNEG 010 Vane Axial Fan 9...
Page 26: ...8 Troubleshooting 26 PNEG 010 Vane Axial Fan Fan Troubleshooting Flow Chart...
Page 30: ...10 Wiring Diagrams 30 PNEG 010 Vane Axial Fan 1 Phase Schematic...
Page 34: ...34 PNEG 010 Vane Axial Fan NOTES...
Page 35: ...10 Wiring Diagrams PNEG 010 Vane Axial Fan 35 3 Phase 230 Volt Schematic...
Page 38: ...38 PNEG 010 Vane Axial Fan NOTES...
Page 39: ...10 Wiring Diagrams PNEG 010 Vane Axial Fan 39 3 Phase 460 Volt Schematic...
Page 42: ...42 PNEG 010 Vane Axial Fan NOTES...
Page 43: ...10 Wiring Diagrams PNEG 010 Vane Axial Fan 43 3 Phase 575 Volt Schematic...