4. Introduction
16
PNEG-1366
12" and 16" Series II Sweep Quick Disconnect Control Box Kit
Capacities and Specifications
1. Use the
to determine the horsepower required.
Due to continual improvements, GSI designs and specifications are subject to change without notice.
Bin
Diameter
12" Series II Sweep
16" Series II Sweep
Drive
HP
Bushel/MT per Hour
Horsepower
Length
Pivot to End
Drive
HP
Bushel/MT per Hour
Horsepower
Length
Pivot to End
5000/125
6000/155
7000/180
8000/205
9000/230
10000/255
36'
2
7.5
7.5
7.5
16.79' (5.12 m)
2
7.5
7.5
7.5
16.85' (5.14 m)
37'
2
7.5
7.5
7.5
17.79' (5.43 m)
2
7.5
7.5
7.5
16.85' (5.14 m)
39'
2
7.5
7.5
7.5
18.79' (5.73 m)
2
7.5
7.5
7.5
17.85' (5.44 m)
40'
2
7.5
7.5
7.5
18.79' (5.73 m)
2
7.5
7.5
7.5
18.75' (5.72 m)
42'
2
7.5
7.5
7.5
19.79' (6.04 m)
2
7.5
7.5
10
19.85' (6.05 m)
43'
2
7.5
7.5
7.5
20.79' (6.34 m)
2
7.5
7.5
10
19.85' (6.05 m)
45'
2
7.5
7.5
7.5
20.79' (6.34 m)
2
7.5
7.5
10
20.85' (6.36 m)
48'
2
7.5
7.5
7.5
22.79' (6.95 m)
2
7.5
10
10
22.85' (6.96 m)
49'
2
7.5
7.5
7.5
22.79' (6.95 m)
2
7.5
10
10
22.85' (6.96 m)
51'
2
7.5
7.5
10
23.79' (7.26 m)
2
7.5
10
10
23.85' (7.27 m)
54'
2
7.5
7.5
10
25.79' (7.86 m)
2
10
10
10
25.85' (7.88 m)
55'
2
7.5
7.5
10
25.79' (7.86 m)
2
10
10
10
25.85' (7.88 m)
57'
2
7.5
7.5
10
26.79' (8.17 m)
2
10
10
10
26.85' (8.18 m)
59'
2
7.5
7.5
10
27.79' (8.47 m)
2
10
10
15
27.85' (8.49 m)
60'
2
7.5
7.5
10
28.79' (8.78 m)
2
10
10
15
28.85' (8.79 m)
62'
2
7.5
7.5
10
29.79' (9.08 m)
2
10
10
15
29.85' (9.10 m)
63'
2
7.5
7.5
10
29.79' (9.08 m)
2
10
10
15
29.85' (9.10 m)
66'
2
7.5
7.5
10
31.79' (9.69 m)
2
10
15
15
31.85' (9.71 m)
68'
2
7.5
7.5
10
32.79' (10.00 m)
2
10
15
15
32.85' (10.01 m)
69'
2
7.5
7.5
10
32.79' (10.00 m)
2
10
15
15
32.85' (10.01 m)
72'
2
7.5
7.5
10
34.79' (10.61 m)
2
15
15
15
34.85' (10.62 m)
75'
2
10
10
10
35.79' (10.91 m)
2
15
15
15
35.85' (10.93 m)
78'
2
10
10
10
37.79' (11.52 m)
2
15
15
15
37.85' (11.54 m)
80'
2
10
10
10
38.79' (11.83 m)
2
15
15
15
38.85' (11.84 m)
81'
2
10
10
10
38.79' (11.83 m)
2
15
15
15
38.85' (11.84 m)
84'
2
10
10
15
40.79' (12.44 m)
2
15
15
15
40.85' (12.45 m)
87'
2
10
10
15
41.79' (12.74 m)
2
15
15
20
41.85' (12.76 m)
88'
2
10
10
15
42.79' (13.05 m)
2
15
15
20
42.85' (13.06 m)
90'
2
10
10
15
43.79' (13.35 m)
2
15
15
20
43.85' (13.37 m)
91'
2
10
10
15
43.79' (13.35 m)
2
15
15
20
43.85' (13.37 m)
92'
2
10
10
15
44.79' (13.66 m)
2
15
20
20
44.85' (13.67 m)
95'
2
10
15
15
45.79' (13.97 m)
2
15
20
20
45.85' (13.98 m)
98'
2
10
15
15
47.79' (14.57 m)
2
15
20
20
47.85' (14.58 m)
105'
3
15
15
20
50.79' (15.48 m)
3
20
20
20
50.85' (15.50 m)
113'
3
15
15
20
54.79' (16.70 m)
3
20
20
20
54.85' (16.72 m)
120'
3
15
15
20
58.79' (17.92 m)
3
20
20
20
58.85' (17.94 m)
Electrical controls and wiring should be installed by a qualified electrician. The
motor disconnect switches and conductor cables should comply with the National
Electrical code and any local codes which apply. Reset and motor starting
stations should be located so the operator can see that all personnel are clear
of the equipment.