4. Fan Specifications
24
PNEG-163-08
Centrifugal Fan
Fan Pad Location
Fan pad should be perpendicular to bin wall. Fan discharge centerline should lie on bin centerline.
Recommended thickness for pad is 4" minimum. Top surface of pad should be 2" below bin
foundation. Fans with downwind heaters require fan pad to be 48" wide and add 33" onto length (D).
IMPORTANT: Fan pad and fan must be level and smooth for proper operation. Vibration problems can
result from improper fan leveling.
Figure 4F
Front of pad should be perpendicular to bin wall. Recommended thickness for fan pad is
4" minimum. Surface of pad should be 2" below the bin foundation. Pad for heater not required.
TR-4734
A = 20" without heater
A = 44" with heater
B = 10"
C = 40"
D = 40"
TR-7048
A = 45" without heater
A = 69" with heater
B = 10"
C = 40"
D = 48"
TR-6918 and
TR-6919
A = 32" without heater
A = 65" with heater
B = 13"
C = 48"
D = 52"
TR-7049
A = 45" without heater
A = 78" with heater
B = 13"
C = 48"
D = 52"
TR-6207
A = 42" without heater
A = 78" with heater
B = 13"
C = 48"
D = 60"
TR-6958
A = 55" without heater
A = 85" with heater
B = 13"
C = 48"
D = 60"
TR-6853 (Double inlet)
A = 54" without heater
A = 88" with heater
B = 28"
C = 100"
D = 60"
TR-4013
A = 36" without heater
B = 13"
C = 48"
D = 60"
TR-6944
A = 48" without heater
B = 13"
C = 48"
D = 60"
Summary of Contents for CF-10
Page 49: ...PNEG 163 08 Centrifugal Fan 49 NOTES...
Page 66: ...66 PNEG 163 08 Centrifugal Fan 8 Schematics Wiring Diagrams Wiring Schematic 230 Volt 1 Phase...
Page 72: ...8 Schematics Wiring Diagrams 72 PNEG 163 08 Centrifugal Fan Wiring Schematic 230 Volt 3 Phase...
Page 74: ...8 Schematics Wiring Diagrams 74 PNEG 163 08 Centrifugal Fan Wiring Schematic 460 Volt 3 Phase...
Page 75: ...8 Schematics Wiring Diagrams PNEG 163 08 Centrifugal Fan 75 Wiring Diagram 460 Volt 3 Phase...