Date:2021.06 

Doc No:GSE-M-0001    Ver.A 

being.When replacing old appliances with new ones, the retailer is legally obligated to take back 
your old 

 

appliance for disposals at least free of charge. 

 

Unpacking and Storing Modules

 

Utmost attention is required when handling the modules. Below marks will be used for 

some caution items when unpacking, transporting, and storing the modules: 

Do not strike and destroy the module.

 

Carry  modules  with  both  hands.  Do  not  use  the 

connection socket as a handle; 

Don’t lacerate the frame during handling and installing. 

Do not stand on the module. 

Do not twist the module.Do not twist the module. 

Do not mark on the rear of the module using sharp objects.

 

The accessible PV module surface shall be smooth 
and free from sharp edges, burrs, etc.,

 

Installing Modules

 

Summary of Contents for GSE260-60P

Page 1: ...munication systems and other electrical applications This manual contains important installation maintenance and safety information The word module as used in this manual refers to one or more PV modu...

Page 2: ...Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwa...

Page 3: ...ill be used for some caution items when unpacking transporting and storing the modules Do not strike and destroy the module Carry modules with both hands Do not use the connection socket as a handle D...

Page 4: ...annual yield optimum orientation and tilt of PV modules is necessary Sunlight shining vertically onto the PV module is the best condition to generate maximum power Artificially concentrated sunlight s...

Page 5: ...over a fire resistant roof covering rated for module s application Use the existing installation holes instead of drilling additional holes for installation Drilling holes shall against the reliabili...

Page 6: ...0001 Ver A A minimum of four clamps must be located in the same colored zone to be certified to tested value If one of the clamps is in the different zone the lowest value should be taken in the accou...

Page 7: ...that wiring is correct before starting the generator If the measured open circuit voltage Voc and short circuit current Isc differ from the specifications then there may be a wiring fault Correct con...

Page 8: ...e factory installed diodes provide proper circuit protection for the system Rating of bypass diodes Current 10A Voltage 50V Others During installation be sure to tie the cable from the junction box to...

Page 9: ...ctions we use a gentle cleaning implement such as a sponge and water from a hose without clean agents to rinse the modules Dried dirt must never be scraped or rubbed scraping and rubbing module surfac...

Page 10: ...Open Circuit Voltage Voc V Tolerance 5 Maximum Power Voltage Vmp V Short Circuit Current Isc A Tolerance 5 Maximu m Power Current Imp A Maximu m Over Current Protectio n A GSE550 144M Mono crystallin...

Page 11: ...otectio n A GSE260 60P Poly crystalline 60 260 38 06 30 80 9 08 8 44 20 A GSE265 60P Poly crystalline 60 265 38 18 31 03 9 12 8 54 20 A GSE270 60P Poly crystalline 60 270 38 30 31 29 9 16 8 63 20 A GS...

Page 12: ...e 144 400 49 39 40 07 10 42 9 99 20 A GSEN395 144M Mono crystalline 144 395 49 18 39 86 10 38 9 91 20 A GSEN390 144M Mono crystalline 144 390 49 04 39 67 10 34 9 83 20 A GSEN385 144M Mono crystalline...

Page 13: ...Date 2021 06 Doc No GSE M 0001 Ver A 13 GSEN315 120M Mono crystalline 120 315 39 90 33 19 10 08 9 49 20 A...