background image

RS485 Connection to Door Controls

 6

System Overview

Door Control

        #1

Door Control

        #2

Door Control

        #3

Door Control

      #4 - 10

RS485 Network to Door Controls

Max Cable Length 1.4 km.

Daisy Chain Configuration Only.

RS485 Network to Controllers

Max number of Controllers 3

Max Cable Length 1.4 km

Controller

      #1

Controller

 #2 - 3

Note: If using a single Controller,

an RS232 cable may be used.

Max cable length 10 meters

Wireless Connection to Door Controls

Door Control

        #1

Door Control

        #2

Door Control

        #3

Door Control

      #5 - 10

RS485 Network to Controllers

Max number of Controllers 3

Max Cable Length 1.4 km

Controller

      #1

Controller

 #2 - 3

Door Control

        #4

 7

System Overview

Note: If using a single Controller,

an RS232 cable may be used.

Max cable length 10 meters

Place a 120ohm

Termination Resistor

across A & B on the last
Door Control in the chain.

Place a 120ohm

Termination Resistor
across A & B on the

Controller

Note: Door Controls can be installed within 30 meters

of the Controller or within 30 meters of any other Door Control

as each Door Control will function as a repeater. Each Door Control
transmits data to/from the Controller. These distances are a guideline.

The actual communication range depends on building shape and

construction methods used.

Summary of Contents for Wi-Plus Controller

Page 1: ...website www globalsecurity ie 4 Installation Instructions 12 Network Diagrams Wiring Diagrams 19 Fingerprint Enrollment Operating Instructions YOUR SECURITY IS OUR PRIORITY Installation Manual V2 08...

Page 2: ...s Wireless RS485 Networks Automatic Backup Facility Database Encryption 10 5000 16 16 16 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description Page 1 Install the Controll...

Page 3: ...ng the rear enclosure to the wall To remove front cover lift tab up and unhook door To re attach front cover hook door over top pip and rotate into position and push tab down to secure 4 Installation...

Page 4: ...rk to Controllers Max number of Controllers 3 Max Cable Length 1 4 km Controller 1 Controller 2 3 Door Control 4 7 System Overview Note If using a single Controller an RS232 cable may be used Max cabl...

Page 5: ...ors will be opened 8 Wiring Diagrams IP4 IP3 0V IP2 IP1 V 0V VOUT OP3 OP4 A B COM 1 2 3 4 OFF ON IP4 IP3 0V IP2 IP1 Inputs TCP_IP 3V Lithium V 0V Power In 12V Outputs OP1 RLY 1 0V 9 Network Diagrams f...

Page 6: ...Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below Configuring GSD Controller Communications OFF ON 1 2 3 4 IP4 IP3 0V IP2...

Page 7: ...d choosing the com port that the serial cable is connected to from the drop down list in the communications section E The Controller icon will change colour from gray off line to green on line to show...

Page 8: ...e 4 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu Once all...

Page 9: ...ill be denied for all cards and PINs on that Door Control Example To Enable PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day Ev...

Page 10: ...nd drag it to the Doors in Current Group to add it to the Door Group Repeat for adding doors as desired Step Description After all users access levels and door control settings have been finalised a f...

Page 11: ...inger Placement 20 Finger Placement Wi BIO Note Good Quality image Fingerprint core is center of sensor window Note Ensure that the core of finger is centered on the sensor window during the enrollmen...

Page 12: ...Correct Finger Placement 22 Finger Placement Wi BIO Incorrect Finger Placement 23 Finger Placement Wi BIO...

Reviews: