GSD GSDn-WEC Installation & User Manual Download Page 2

 2

 3

Technical Specification

Power Supply

                      

230 VAC

Current consumption    

30mA

Fuse Rating

230VAC 315mA T

Moisture Resistance

 

 Indoor Use Only

Dimensions  

 

                              

W.

  260mm 

D. 

262mm 

H.

 55mm

Technical Specs - GSD Wi-Enterprise Controller

Power Supply

                      

12 DC

Current consumption    

110mA

Current consumption with load (max)

145mA

Relay Contact Rating

5 Amps /230V ac

Operating Temperature

- 20  C   to +60  C

Moisture Resistance   

IP 67 ( IP65 on Wi-Bio )

Dimensions  - Flush Mount

 

W.

 87mm 

D. 

21mm 

H.

 119mm

       - Surface Mount  

W.

 87mm 

D. 

35mm 

H.

 119mm

Technical Specs - Wi-

Enterprise

 Door Controls

Features

Doors controlled
Users
User Groups
Time Zones
Door Groups
Reporting Facility
Challenge Facility
Logging
Input/Output Mapping
Supports Wireless & RS485 Networks
Automatic Backup Facility
Database Encryption

20

20000

128
128
128

Yes
Yes

Unlimited

CCTV & Lift control

Yes
Yes
Yes

Installation Steps

Step    Description

       Page

   1        Install the Controller using the Installation Diagrams

        4-5

   2        Wire the Controller using the Wiring Diagrams

         8

   3        Install and wire each Door Control. Refer to the Door Control

             Manual for instructions.

   4        Connect the Controller to the PC using Network Diagrams

       9-11

   5        Restoring Factory Defaults

        11

   6         Setting up TCP-IP                                                                                12

   6        Phase 1- Setting up the GSD Controller                                             14

   7        Phase 2 - Configuring the GSD Controller                     

        15

   8        Phase 3 - Enrolling Door Controls 

      16-18

   9        Phase 4 - Configuring Users 

        19

  10       Phase 5 - Configuring Access Levels              

        20

  11       Phase 6 - Downloading Configuration

        20

  12       Enrolling User Fingerprints

        21

  13       Correct Finger Placement techniques                                             22-25

Installation Steps

Summary of Contents for GSDn-WEC

Page 1: ...less Network System GSD Wi Max System is the next generation in access control solutions It provides a Wireless Network throughout the premises giving the convenience and security of a fully networked...

Page 2: ...Output Mapping Supports Wireless RS485 Networks Automatic Backup Facility Database Encryption 20 20000 128 128 128 Yes Yes Unlimited CCTV Lift control Yes Yes Yes Installation Steps Step Description...

Page 3: ...pull out on right and slide left to remove cover pull forward on right and slide left mount with 4 x 1 5 inch No 8 Security Type screws rear tamper switch cable entry cable entry cable entry cable en...

Page 4: ...view 50 meters 50 meters 50 meters 50 meters 50 meters 50 meters Note If using a single Controller an RS232 cable may be used Max cable length 10 meters RS485 Connection to Door Controls Door Control...

Page 5: ...Warning Installation should only be carried out by a suitably qualified person only Cable Tie retaining clips Main Input Cable 230VAC Neutral Earth Live Remove Battery Tab Pull 9 Network Diagrams for...

Page 6: ...he GSD Controller address Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW3 ON only The Controller Address is set by configuring the Dip switches as shown below C...

Page 7: ...e new IP Address settings are applied 9 Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Controller Note Reset the IP address on...

Page 8: ...troller is on line 15 Operation Instructions Phase 2 Configuring the GSD Controller Step Description 1 Open the Doors tab in the main menu to add the required number of new doors to be part of this ne...

Page 9: ...Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication 17 Operation Instructions Phase 3 Enrolling Door Controls Note For Wired 485 Door Controls right click on the Co...

Page 10: ...rol Example Disabling cards fobs Enabling PIN codes only on a Wi PIN Prox Set the Timed Action Card or PIN to Inactive and setting the Timed Action PIN Only to All day Every Day This will grant access...

Page 11: ...om the All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Step Description After all users access levels and door control...

Page 12: ...ot store the finger print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Incorrect F...

Page 13: ...Correct Finger Placement 24 Finger Placement Wi BIO Incorrect Finger Placement 25 Finger Placement Wi BIO...

Page 14: ...14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Ctrl Door No Door Type Door Location Name Walk Test 1 2 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Ctrl Door No Door Typ...

Reviews: