EN
www.garsaco.com
| 11
Problem
Cause
Solution
It does not work
It is not connected to a 12V AC
electrical connection.
Connect it to a 12V AC safety
transformer.
An electric transformer is being used.
Replace the transformer for a
conventional safety pool.
Low light or flashing
Possible excessive voltage drop
through the cable.
In multi-voltage transformers,
select an appropriate voltage
output or compensate the voltage
drop with a larger cable.
Thermal protection against over
temperatures has been activated.
Check that the cooling holes of the
projector are clear of obstacles.
It does not change color or
sequence.
In RGB lights, for
Ref,: 000705133.
The command is not linked to the
controller.
Check that it is properly con-
nected.
Each projector emits different
chimes
In RGB lights, for
Ref,: 000705133.
The projectors are not synchronized.
Perform a long press, from 1 to 3
seconds and they will be placed
in white.