Version
1.1
Date
January 28th, 2019
Page
22/ 47
Title
USER MANUAL
Prepared
by
Reviewed
by
Approved
by
© 2019 GS Teletech Inc. All rights reserved
22
Parameter
Status
Control
Description
Donor Site ID
○
Write the Donor Site Info. That install a repeater
Temp
○
Current Temperature in repeater
Temp. High Limit
○
Control Temp. Alarm Threshold
ILC
○
ILC Function On/Off
ILC Value
○
ILC Level Control
Alarm Delay
○
Set the delay time that transmit from
repeater to Server
UL AMP
○
UL AMP On Off
DFM Version
○
Display a DFM Software Version
FPGA Version
○
Display a DL/UL FPGA Software Version
DFM Serial Number
○
Display a DFM Serial Number
TDD Mode
○
T-Sync Detect Mode Control
Table 11. GST-IC-ELITE-TNR Status Monitoring and Control Parameters
6.2.
Alarm Monitoring
•
All of alarms in Repeater are able to check thru Local Maintenance Port & Remote Site
•
Provide to Alarm Mask function in order to ignoring unnecessary alarm
Parameter
Alarm conditions
Recovery
LTE
DL Over Output
Output power exceed a setting value (Band
independently)
< Hysteresis 1dB
DL Low Output
Band Output power < Output power Low limit value
Opposite Condition
DL Low RSSI
Band RSSI < Input Low limit value
Opposite Condition
DL VSWR
Return loss < 5dB
Return loss > 7dB
DL Shutdown
By Over Output Alarm, By PLL Alarm, By Amp H/W Fail
By Low Isolation
Alarm Off
AMP H/W Fail
Power AMP gain is poor
AMP Output Power < DSP Output Power -20dB over 30sec
Power AMP Gain OK
DL Low Isolation
Isolation < 70dB
Opposite Condition
UL Low Isolation
Isolation < 70dB
Opposite Condition